Credibility assessment of patient-specific modeling in transcatheter aortic valve implantation. I. A population-based validation of patient-specific modeling.
Article in APL bioengineering, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed.
- Fully coupled patient-specific fluid-structure interaction modeling of post-TAVI hemodynamics compared with echocardiographic measurements.Biomechanics and modeling in mechanobiology · 2026Article
- Erratum: "Credibility assessment of patient-specific modeling in transcatheter aortic valve implantation. I. A population-based validation of patient-specific modeling" [APL Bioeng.APL bioengineering · 2026Article
- AI-Enabled Reduction of Animal Use in Cardiovascular Translational Medicine: Regulatory and Technological Perspectives.Life (Basel, Switzerland) · 2025Review
- Credibility assessment of patient-specific modeling in transcatheter aortic valve implantation-Part 2: Uncertainty quantification and sensitivity analysis.APL bioengineering · 2025Article
Corrections and comments
- Erratum issued
Authors and funding
9 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Transcatheter aortic valve implantation (TAVI) has become a standardized treatment for aortic valve stenosis, supported by computational modeling to enhance procedural planning. However, the credibility of TAVI simulations requires rigorous validation following regulatory standards. This study aims to perform a population-based validation of the structural and hemodynamic simulation performance of the SAPIEN 3 (S3) Ultra device by comparing computational predictions with clinical post-TAVI data, following the ASME V&V 40 framework. A patient-specific structural model followed by fluid-structure interaction was developed to simulate S3 deployment and then assess post-TAVI hemodynamics in 20 patients. Structural parameters (device diameters) and hemodynamic indices (effective orifice area, EOA, and transmural pressure gradient, TPG) were extracted. Validation was performed using empirical cumulative distribution function (ECDF) analysis, with an acceptance threshold of 5% for model credibility. EOA and TPG predictions showed reasonable agreement with echocardiographic data (errors within 10%). ECDF-based comparison demonstrated a high level of accuracy for device diameters (≤5% area metric), whereas hemodynamic parameters exhibited slightly greater discrepancies, potentially due to clinical measurement variability. This study establishes a robust computational validation framework for patient-specific TAVI modeling, ensuring regulatory compliance and clinical applicability. These findings highlight the potential of
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.