Evidence map›Paper›PMID 41018650›Full record

ArticleACS omega2025

Time-Dependent Heat Transfer Coefficients of Standard Cans during Pasteurization.

Hussain Albattah Alhusni, Suresh Krishnan

Abstract read
In one paragraph

Article in ACS omega, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Hussain Albattah AlhusniDepartment of Chemical Engineering, College of Engineering and Technology, SRM Institute of Science and Technology, Kattankulathur, Tamil Nadu, India, 603203.ORCID https://orcid.org/0009-0002-6010-3178
Suresh KrishnanDepartment of Chemical Engineering, College of Engineering and Technology, SRM Institute of Science and Technology, Kattankulathur, Tamil Nadu, India, 603203.ORCID https://orcid.org/0000-0002-2188-981X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Canned food products are pasteurized by heating them in hot water to deactivate enzymes, followed by rapid cooling. We utilized computational fluid dynamics (CFD) to analyze heat transfer in juice cans of 330 mL, 500 mL, and 1000 mL placed in water baths set at 60 °C, 80 °C, and 25 °C. Two methods were employed to study heat transfer: a detailed conjugate heat transfer simulation and a simplified boundary condition approach that applies time-averaged heat transfer coefficients to the can wall without modeling the surrounding bath fluid. The conjugate heat transfer simulation's time-temperature profile aligned with experimental results within a 2% margin. The three stages of heat transfer during heating and cooling cycles significantly affected the profile inside the sealed container, making this simulation essential for determining effective pasteurization come-up times. Results indicated that the heat transfer coefficients on both the inner and outer surfaces were nearly identical during heating and cooling. The temperature contours inside the container showed spatial patterns similar to those in both cycles. As expected from natural convection effects, a cold spot was consistently found near the bottom and a hot spot was consistently found near the top. Additionally, increasing the water bath temperature from 60 to 80 °C can shorten come-up times by 12-15%.

Identifiers

PMID41018650
PMCPMC12461314

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.