Evidence map›Paper›PMID 41018316›Full record

ArticleCureus2025

Reference Range for the Automated Fragmented Red Cell Parameter and Its Diagnostic Utility in Red Blood Cell (RBC) Fragment Quantification: A Prospective Study.

Ginni Bharti, Tushar Sehgal, Hemchandra Pandey, Hem C Sati

Abstract read
In one paragraph

Article in Cureus, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Ginni BhartiLaboratory Medicine, All India Institute of Medical Sciences, New Delhi, New Delhi, IND.
Tushar SehgalLaboratory Medicine, All India Institute of Medical Sciences, New Delhi, New Delhi, IND.
Hemchandra PandeyTransfusion Medicine, All India Institute of Medical Sciences, New Delhi, New Delhi, IND.
Hem C SatiBiostatistics, All India Institute of Medical Sciences, New Delhi, New Delhi, IND.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background The automated measurement of fragmented red blood cells (FRCs) is a recently introduced parameter available on modern hematology analyzers, including the XN-Series™ Automated Hematology Analyzers (Sysmex Corporation, Kobe, Japan). Its clinical relevance lies in its potential to correlate with schistocyte counts, which is a critical diagnostic step in thrombotic microangiopathies and related disorders, as their presence reflects microangiopathic red cell fragmentation and guides urgent clinical decision-making. Schistocyte quantifications are traditionally assessed manually on stained peripheral blood smears using light microscopy. However, the accuracy of FRC measurement is highly dependent on the specific technology and methodology employed by each analyzer, making the establishment of instrument-specific reference ranges essential. This study aimed to establish a reference range for FRC and to evaluate the correlation between manual schistocyte counts and automated FRC measurements. Methods We analyzed 179 normal samples from voluntary blood donors using the XN-Series™ automated hematology analyzer to establish the reference range for FRC. In addition, we evaluated the influence of other red blood cell (RBC) parameters on FRC measurements. To assess the diagnostic performance of FRC, we further analyzed 100 patient samples by comparing the automated FRC values with manual schistocyte counts performed on stained peripheral blood smears, using Bland-Altman analysis for agreement assessment. Results Based on the analysis of 179 healthy samples, the reference interval for the absolute FRC count (FRC#) was 0.0 to 0.125/µL, and for the FRC percentage (FRC%), it was 0.0 to 0.00515%. Elevated Hypo-He (hypo hemoglobin equivalent) values (red cells with hemoglobin content <17 pg) were associated with spurious increases in FRC measurements, suggesting potential analytical interference. In a separate cohort of 100 patient samples, an FRC% threshold of <1% demonstrated a negative predictive value (NPV) of 70% for excluding the presence of schistocytes on peripheral blood smear. Bland-Altman analysis comparing manual schistocyte counts with automated FRC% revealed a mean bias of 0.287, with 95% limits of agreement ranging from -2.2 to 2.8, indicating moderate agreement between the two methods. Conclusion Establishing reference ranges for FRC not only enhances clinical interpretation but also provides valuable feedback to hematology analyzer manufacturers for refining automated smear-generation rules. As an initial screening tool, the FRC parameter could help safely exclude over two-thirds of samples (NPV = 70%) from manual review, reducing the burden of time-intensive schistocyte quantification. Such selective flagging has the potential to improve laboratory efficiency without compromising patient safety, enabling laboratory physicians to prioritize and triage cases more effectively. The upper reference limit was well below the ≥1% schistocyte threshold for thrombotic microangiopathic anemia (TMA), supporting the role of elevated FRC as a trigger for manual smear review, which remains indispensable whenever TMA is clinically suspected.

Indexed as

blood film microscopyfragmented red blood cellshematology analyserhemolytic uremic syndrome (hus)laboratory automationreference rangettp (thrombotic thrombocytopenic purpura)

Identifiers

PMID41018316
PMCPMC12463579

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.