ArticleFrontiers in oncology2025

A comparative study of postural fixation techniques for radiotherapy in upper abdominal malignancies.

Ji-Hua Han, Dong-Cheng He, Xiao-Ye Zhang, Yan Zhang, Jun Hong, Ting-Ting Shi, Zhi-Jian Zhu

Abstract read
In one paragraph

Article in Frontiers in oncology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Ji-Hua Han *Department of Radiation Oncology, The Affiliated Huaian No.1 People's Hospital of Nanjing Medical University, Huai'an, China.
Dong-Cheng He *Department of Radiation Oncology, The Affiliated Huaian No.1 People's Hospital of Nanjing Medical University, Huai'an, China.
Xiao-Ye ZhangDepartment of Radiation Oncology, The Affiliated Huaian No.1 People's Hospital of Nanjing Medical University, Huai'an, China.
Yan ZhangDepartment of Radiation Oncology, The Affiliated Huaian No.1 People's Hospital of Nanjing Medical University, Huai'an, China.
Jun HongDepartment of Radiation Oncology, The Affiliated Huaian No.1 People's Hospital of Nanjing Medical University, Huai'an, China.
Ting-Ting ShiDepartment of Radiation Oncology, The Affiliated Huaian No.1 People's Hospital of Nanjing Medical University, Huai'an, China.
Zhi-Jian ZhuDepartment of Radiation Oncology, The Affiliated Huaian No.1 People's Hospital of Nanjing Medical University, Huai'an, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: In this study, we investigated the impact of two distinct postural fixation techniques on the incidence of setup errors in patients with upper abdominal malignancies. Methods: Seventy-seven patients with upper abdominal malignancies were divided into two groups: an observation group comprising 31 patients managed with a combination of thermoplastic body film and an air bag, and a control group consisting of 46 patients managed solely with thermoplastic body film. Prior to radiotherapy, a cone-beam computed tomography (CBCT) scan was performed, followed by registration of CBCT scans and positioning computed tomography (CT) images. Setup errors along the X (left/right), Y (superior/inferior), and Z (anterior/posterior) axes of the two groups were recorded and analyzed. A Wilcoxon rank-sum test was used for data analysis. Random errors (Σ), systematic errors (σ), and planning target volume (PTV) margins (MPTV) were evaluated. Results: The three-directional setup errors of the observation group [X: 1.9 (0.90, 2.73), Y: 2.5 (1.48, 3.7), Z: 1.4 (0.78, 2.3)] and the resultant displacement vector [T: 3.97 (3.08, 5.32)] exhibited lower magnitudes compared to those observed in the control group [X: 2.3 (1.1, 3.6), Y: 3.5 (2.1, 5.4), Z: 1.8 (0.9, 3.1); T: 5.51 (4.18, 7.25)]. These differences were statistically significant (p < 0.05). Notably, the Σ, σ, and MPTV in the observation group were consistently smaller than those observed in the control group. Conclusion: The combined use of thermoplastic body film and an air bag in postural fixation significantly reduces setup errors during radiotherapy for patients with upper abdominal tumors. This combined approach enhances the precision of postural alignment, thereby improving positional repeatability and reducing both random and systematic errors. Furthermore, this method is associated with decreased planning target volume margins, providing better protection to adjacent normal tissue structures.

Indexed as

postural fixationPTV marginrandom errorsetup errorsystematic error

Identifiers

PMID41018076
PMCPMC12463582