Evidence map›Paper›PMID 41015774›Full record

ArticleEye and vision (London, England)2025

Association between axial elongation and corneal power distribution changes induced by aspheric orthokeratology lenses.

Mengdi Li, Kailang Zhang, Hua Bi, Xingyi Guo, Lihua Li, Bin Zhang, Xiaoyan Yang

Abstract read
In one paragraph

Article in Eye and vision (London, England), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Mengdi LiTianjin Eye Hospital, Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin Eye Hospital Optometric Center, No 4. Gansu Rd, Heping District, Tianjin, 300020, China.
Kailang ZhangTianjin Eye Hospital, Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin Eye Hospital Optometric Center, No 4. Gansu Rd, Heping District, Tianjin, 300020, China.
Hua BiCollege of Optometry, Nova Southeastern University, 3301 College Avenue, Davie, FL, 33314, USA.
Xingyi GuoTianjin Eye Hospital, Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin Eye Hospital Optometric Center, No 4. Gansu Rd, Heping District, Tianjin, 300020, China.
Lihua LiTianjin Eye Hospital, Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin Eye Hospital Optometric Center, No 4. Gansu Rd, Heping District, Tianjin, 300020, China.
Bin Zhang *College of Optometry, Nova Southeastern University, 3301 College Avenue, Davie, FL, 33314, USA. bz52@nova.edu.
Xiaoyan Yang *Tianjin Eye Hospital, Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin Eye Hospital Optometric Center, No 4. Gansu Rd, Heping District, Tianjin, 300020, China. yanzitjsykyy@163.com.

Funding

the open project of Institute of Optometry and Vision Science in Nankai University NKSGP202307the open project of Institute of Optometry and Vision Science in Nankai University NKSGY202304
6 · The paper itself

Abstract

purposeThis study investigated how aspheric lens design changes the corneal power distribution and how such changes are associated with the axial elongation in myopic children who underwent orthokeratology.

methodsThis retrospective study of 116 eyes from children aged 8-13 years were enrolled and fitted with three types of lenses: fully spherical lenses (Alpha, n = 45), those with an aspheric alignment curve (AC) and a spherical base curve (BC) (Dreamlite, n = 37), and lenses with a partly aspheric BC and an aspheric AC (Myok, n = 34). Axial lengths were measured at baseline, 6 and 12 months. Corneal topography maps obtained at baseline and after 1 month of lens wear were analyzed with Fourier decomposition: the F0 (spherical), F1 (asymmetry), F2 (regular astigmatism), and F3 (higher-order irregularity) components were extracted and quantified across ten concentric rings with 0.5 mm width.

resultsThe 1-year axial elongation was 0.26 ± 0.21 mm, 0.16 ± 0.19 mm, and 0.10 ± 0.19 mm for the Alpha, Dreamlite, and Myok groups, respectively (P < 0.001). In the 1-month maps, F0 and F1 peaked at the mid-periphery, and declined peripherally. Dreamlite exhibited F0 values greater than those of Alpha (mean difference: 0.02-0.46 D) within the central 2 mm (P < 0.01) and lower than Myok's values (mean difference: 0.66-1.05 D) in the peripheral 3 to 4.5 mm (P < 0.01). Dreamlite also displayed greater F1 compared to Alpha (mean difference: 0.68-0.78 D) within the 1 to 2 mm rings (P < 0.01) but showed no significant difference from Myok. F2 and F3 remained flat and small. Three components, F0, F1, and F3, were negatively associated with axial elongation in these children (P < 0.001).

conclusionLenses featuring an aspheric AC resulted in reduced axial elongation and increased spherical power and asymmetry in the central cornea, while lenses with a partly aspherical BC improved spherical power in the mid-periphery. A smaller axial elongation was associated with greater post treatment central cornea asymmetry.

Indexed as

Aspheric designAxial elongationCorneal power distributionOrthokeratology

Identifiers

PMID41015774
PMCPMC12476625

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.