Evidence map›Paper›PMID 41012933›Full record

ArticleSensors (Basel, Switzerland)2025

Target Recognition Based on Millimeter-Wave-Sensed Point Cloud Using PointNet++ Model.

Xianxian He, Haiyu Ding, Rongyan Xi, Jing Dong, Jing Jin, Qixing Wang, Chunju Shao, Xiao Dong, Yunhua Zhang

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Xianxian HeFuture Research Laboratory, China Mobile Research Institute, Beijing 100053, China.
Haiyu DingFuture Research Laboratory, China Mobile Research Institute, Beijing 100053, China.
Rongyan XiFuture Research Laboratory, China Mobile Research Institute, Beijing 100053, China.ORCID 0000-0002-1135-3843
Jing DongFuture Research Laboratory, China Mobile Research Institute, Beijing 100053, China.
Jing JinFuture Research Laboratory, China Mobile Research Institute, Beijing 100053, China.
Qixing WangFuture Research Laboratory, China Mobile Research Institute, Beijing 100053, China.
Chunju ShaoFuture Research Laboratory, China Mobile Research Institute, Beijing 100053, China.
Xiao DongCAS Key Laboratory of Microwave Remote Sensing, National Space Science Center, Chinese Academy of Sciences, Beijing 100190, China.
Yunhua ZhangCAS Key Laboratory of Microwave Remote Sensing, National Space Science Center, Chinese Academy of Sciences, Beijing 100190, China.ORCID 0000-0001-8125-9425

Funding

joint project of China Mobile Research Institute & X-NETNational Natural Science Foundation of China 61971402National Science and Technology Major Project of China 2025ZD1302000
6 · The paper itself

Abstract

During walking, the human lower limbs primarily support the body and drive forward motion, while the arms exhibit greater variability and flexibility without bearing such loads. In gait-based target recognition, collecting exhaustive arm-motion data for training is challenging, and unseen arm movements during testing may degrade the performance. This paper investigates the impact of arm movements on radar-based gait recognition and proposes a gait recognition method using extracted lower limb motion data to mitigate interference from different arm motions. Gait data is collected via a millimeter-wave radar sensor encompassing four kinds of common arm movements, including natural arm swings, object-holding states, and irregular arm motions, from 11 volunteers. Using extracted lower limb motion data, millimeter wave point-cloud gait datasets covering diverse arm motions are generated. Three gait recognition experiments are conducted for comparing the performances of our proposed method using only lower limb data and existing method using all limb data, both based the on PointNet++ model. And the experimental results show that our method consistently outperforms existing methods, with a 22.9-percent improvement in accuracy. Results also show that the proposed method can enhance feature extraction, accelerate convergence, and achieve higher accuracy, especially with limited samples, and the highest recognition accuracy reaches 96.9%. In addition, in unseen arm movement cases, our method significantly outperforms existing methods, demonstrating superior robustness and recognition accuracy.

Indexed as

GaitAlgorithmsArmHumansLower ExtremityMovementRadarWalkingextracted limb motion datagait recognitionmillimeter-wave radar point cloudPointNet++ model

Identifiers

PMID41012933
PMCPMC12473999

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.