ArticleSensors (Basel, Switzerland)2025
Target Recognition Based on Millimeter-Wave-Sensed Point Cloud Using PointNet++ Model.
Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Measurement Method for Mold Slag Thickness in Continuous Casting Mold Using Millimeter-Wave Radar and Eddy Current Sensors.Sensors (Basel, Switzerland) · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
Abstract
During walking, the human lower limbs primarily support the body and drive forward motion, while the arms exhibit greater variability and flexibility without bearing such loads. In gait-based target recognition, collecting exhaustive arm-motion data for training is challenging, and unseen arm movements during testing may degrade the performance. This paper investigates the impact of arm movements on radar-based gait recognition and proposes a gait recognition method using extracted lower limb motion data to mitigate interference from different arm motions. Gait data is collected via a millimeter-wave radar sensor encompassing four kinds of common arm movements, including natural arm swings, object-holding states, and irregular arm motions, from 11 volunteers. Using extracted lower limb motion data, millimeter wave point-cloud gait datasets covering diverse arm motions are generated. Three gait recognition experiments are conducted for comparing the performances of our proposed method using only lower limb data and existing method using all limb data, both based the on PointNet++ model. And the experimental results show that our method consistently outperforms existing methods, with a 22.9-percent improvement in accuracy. Results also show that the proposed method can enhance feature extraction, accelerate convergence, and achieve higher accuracy, especially with limited samples, and the highest recognition accuracy reaches 96.9%. In addition, in unseen arm movement cases, our method significantly outperforms existing methods, demonstrating superior robustness and recognition accuracy.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.