ArticleMicromachines2025
Dual-Mode Flexible Pressure Sensor Based on Ionic Electronic and Piezoelectric Coupling Mechanism Enables Dynamic and Static Full-Domain Stress Response.
Article in Micromachines, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
Abstract
Flexible pressure sensors have shown promise applications in scenarios such as robotic tactile sensing due to their excellent sensitivity and linearity. However, the realization of flexible pressure sensors with both static and dynamic response capabilities still face significant challenges due to the properties of the sensing materials themselves. In this study, we propose a flexible pressure sensor that integrates piezoelectric and ionic capacitance mechanisms for full-domain response detection of dynamic and static forces: a "sandwich" sensing structure is constructed by printing a mixture of multi-walled carbon nanotubes (MWCNTs) onto the surface of the upper and lower electrodes, and sandwiching a polyvinylidene fluoride (PVDF) thin film between the electrodes. The device exhibits a sensitivity of 0.13 kPa
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.