Evidence map›Paper›PMID 41011881›Full record

ReviewMicromachines2025

Advances in Laser Linewidth Measurement Techniques: A Comprehensive Review.

Zhongtian Liu, Hao Zheng, Chunwei Li, Zunhan Qi, Cunwei Zhang, Tie Li, Zhenxu Bai

Abstract readReview
In one paragraph

Review in Micromachines, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Zhongtian LiuCenter for Advanced Laser Technology, School of Electronics and Information Engineering, Hebei University of Technology, Tianjin 300401, China.
Hao ZhengCenter for Advanced Laser Technology, School of Electronics and Information Engineering, Hebei University of Technology, Tianjin 300401, China.
Chunwei LiCenter for Advanced Laser Technology, School of Electronics and Information Engineering, Hebei University of Technology, Tianjin 300401, China.
Zunhan QiCenter for Advanced Laser Technology, School of Electronics and Information Engineering, Hebei University of Technology, Tianjin 300401, China.
Cunwei ZhangCenter for Advanced Laser Technology, School of Electronics and Information Engineering, Hebei University of Technology, Tianjin 300401, China.
Tie LiCenter for Advanced Laser Technology, School of Electronics and Information Engineering, Hebei University of Technology, Tianjin 300401, China.
Zhenxu BaiCenter for Advanced Laser Technology, School of Electronics and Information Engineering, Hebei University of Technology, Tianjin 300401, China.ORCID 0000-0003-2040-833X

Funding

National Key Research and Development Program of China 2024YFE0206000National Natural Science Foundation of China 62375076 and 61927815Natural Science Foundation of Hebei Province F2023202063Natural Science Foundation of Tianjin City 22JCYBJC01100Natural Science Research Program for Higher Education Institutions in Hebei Province JCZX2025003
6 · The paper itself

Abstract

As a key parameter that defines the spectral characteristics of lasers, the precise measurement of laser linewidth is crucial for a wide range of advanced applications. This review systematically summarizes recent advances in laser linewidth measurement techniques, covering methods applicable from GHz-level broad linewidths to sub-Hz ultranarrow regimes. We begin by presenting representative applications of lasers with varying linewidth requirements, followed by the physical definition of linewidth and a discussion of the fundamental principles underlying its measurement. For broader linewidth regimes, we review two established techniques: direct spectral measurement using high-resolution spectrometers and Fabry-Pérot interferometer-based analysis. In the context of narrow-linewidth lasers, particular emphasis is placed on the optical beating method. A detailed comparison is provided between two dominant approaches: power spectral density (PSD) analysis of the beat signal and phase-noise-based linewidth evaluation. For each technique, we discuss the working principles, experimental configurations, achievable resolution, and limitations, along with comparative assessments of their advantages and drawbacks. Additionally, we critically examine recent innovations in ultra-high-precision linewidth metrology. This review aims to serve as a comprehensive technical reference for the development, characterization, and application of lasers across diverse spectral regimes.

Indexed as

Fabry–Pérot interferometrylinewidth measurementphase noisespectral analysis

Identifiers

PMID41011881
PMCPMC12471392

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.