Evidence map›Paper›PMID 41007198›Full record

ArticleBioengineering (Basel, Switzerland)2025

Emulating Hyperspectral and Narrow-Band Imaging for Deep-Learning-Driven Gastrointestinal Disorder Detection in Wireless Capsule Endoscopy.

Chu-Kuang Chou, Kun-Hua Lee, Riya Karmakar, Arvind Mukundan, Pratham Chandraskhar Gade, Devansh Gupta, Chang-Chao Su, Tsung-Hsien Chen, Chou-Yuan Ko, Hsiang-Chen Wang

Abstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Review
  2. AI-Enhanced Vibrational Capsule for Minimally Invasive Detection of Abnormal Bowel Tissue.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
    Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Chu-Kuang ChouDivision of Gastroenterology and Hepatology, Department of Internal Medicine, Ditmanson Medical Foundation Chia-Yi Christian Hospital, Chia-Yi 60002, Taiwan.ORCID 0000-0003-2588-6883
Kun-Hua LeeDepartment of Trauma, Changhua Christian Hospital, No. 135, Nanxiao St., Changhua City 50006, Taiwan.ORCID 0009-0009-6811-4614
Riya KarmakarDepartment of Mechanical Engineering, National Chung Cheng University, No. 168, University Rd., Min Hsiung, Chia-Yi 62102, Taiwan.
Arvind MukundanDepartment of Mechanical Engineering, National Chung Cheng University, No. 168, University Rd., Min Hsiung, Chia-Yi 62102, Taiwan.ORCID 0000-0002-7741-3722
Pratham Chandraskhar GadeInformation Technology Department, Sanjivani College of Engineering, Kopargaon 423603, Maharashtra, India.
Devansh GuptaComputer Science and Engineering Department, Thapar Institute of Engineering & Technology, Patiala 147001, Punjab, India.ORCID 0009-0001-3210-8388
Chang-Chao SuDivision of Gastroenterology and Hepatology, Department of Internal Medicine, Ditmanson Medical Foundation Chia-Yi Christian Hospital, Chia-Yi 60002, Taiwan.
Tsung-Hsien ChenDepartment of Internal Medicine, Ditmanson Medical Foundation Chia-Yi Christian Hospital, Chia-Yi 60002, Taiwan.ORCID 0000-0002-1542-1495
Chou-Yuan KoDepartment of Gastroenterology, Kaohsiung Armed Forces General Hospital, No. 2, Zhongzheng 1st. Rd., Lingya District, Kaohsiung City 80284, Taiwan.
Hsiang-Chen WangDepartment of Mechanical Engineering, National Chung Cheng University, No. 168, University Rd., Min Hsiung, Chia-Yi 62102, Taiwan.ORCID 0000-0003-4107-2062

Funding

Ditmanson Medical Foundation Chia-Yi Christian Hospital R113-33Kaohsiung Armed Forces General Hospital KAFGH_D_114029National Science and Technology Council NSTC 113-2221-E-194-011-MY3, 113-2634-F-194-001Southern Taiwan Science Park 113CM-1-02
6 · The paper itself

Abstract

Diagnosing gastrointestinal disorders (GIDs) remains a significant challenge, particularly when relying on wireless capsule endoscopy (WCE), which lacks advanced imaging enhancements like Narrow Band Imaging (NBI). To address this, we propose a novel framework, the Spectrum-Aided Vision Enhancer (SAVE), especially designed to transform standard white light (WLI) endoscopic images into spectrally enriched representations that emulate both hyperspectral imaging (HSI) and NBI formats. By leveraging color calibration through the Macbeth Color Checker, gamma correction, CIE 1931 XYZ transformation, and principal component analysis (PCA), SAVE reconstructs detailed spectral information from conventional RGB inputs. Performance was evaluated using the Kvasir-v2 dataset, which includes 6490 annotated images spanning eight GI-related categories. Deep learning models like Inception-Net V3, MobileNetV2, MobileNetV3, and AlexNet were trained on both original WLI- and SAVE-enhanced images. Among these, MobileNetV2 achieved an F1-score of 96% for polyp classification using SAVE, and AlexNet saw a notable increase in average accuracy to 84% when applied to enhanced images. Image quality assessment showed high structural similarity (SSIM scores of 93.99% for Olympus endoscopy and 90.68% for WCE), confirming the fidelity of the spectral transformations. Overall, the SAVE framework offers a practical, software-based enhancement strategy that significantly improves diagnostic accuracy in GI imaging, with strong implications for low-cost, non-invasive diagnostics using capsule endoscopy systems.

Indexed as

esophagitisgastrointestinal diseaseshyperspectral imagingnarrow band imagingpolypsspectrum aided visual enhancerulcerative colitiswhite light imagingwireless capsule endoscopy

Identifiers

PMID41007198
PMCPMC12467974

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.