ArticleBioengineering (Basel, Switzerland)2025
Optimization and Analysis of Tangential Component Orientations in OPM-MEG Sensor Array.
Article in Bioengineering (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
Optically pumped magnetometers (OPMs) have brought a transformative advancement to magnetoencephalography (MEG), enabling flexible, noncryogenic, and wearable neuroimaging systems. In particular, the development of triaxial OPM sensors allows for simultaneous measurement of full magnetic field vectors, including both radial and additional tangential components. Previous studies have shown that incorporating tangential components helps enhance the separation between neural signals and external interference, but their optimal configurations remain unclear. This study systematically investigated the impact of tangential component configurations on array sensitivity and the lead field correlation coefficient (R12) in triaxial OPM-MEG sensor arrays, considering tangential component rotations, relative orientations of sensor and source, source depths, and head model types. Based on the above analysis, we proposed an optimization strategy aimed at minimizing R12, referred to as R12-minimization array optimization (RMAO), to explore the optimal configuration of tangential components. The simulation results showed that the proposed method significantly enhanced sensitivity to cortical sources and effectively suppressed external interference, enabling more accurate source localization. This study highlights the critical role of tangential components in improving system performance and provides theoretical foundation and methodological guidance for the design of triaxial OPM-MEG sensor arrays.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.