Postsurgical Temporary Epicardial Pacing: Electrophysiological Implications of Contemporary Pacing Lead Designs.

Intisar Ahmed, Chloe Netlefold, Robert D Anderson, Stephane Masse, Melanie R Burg, Tirone E David, Jane Heggie, Maral Ouzounian, Kumaraswamy Nanthakumar

Abstract read
In one paragraph

Article in CJC open, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Intisar AhmedToronto General Hospital, University of Toronto, Toronto, Ontario, Canada.
Chloe NetlefoldToronto General Hospital, University of Toronto, Toronto, Ontario, Canada.
Robert D AndersonToronto General Hospital, University of Toronto, Toronto, Ontario, Canada.
Stephane MasseToronto General Hospital, University of Toronto, Toronto, Ontario, Canada.
Melanie R BurgToronto General Hospital, University of Toronto, Toronto, Ontario, Canada.
Tirone E DavidToronto General Hospital, University of Toronto, Toronto, Ontario, Canada.
Jane HeggieToronto General Hospital, University of Toronto, Toronto, Ontario, Canada.
Maral OuzounianToronto General Hospital, University of Toronto, Toronto, Ontario, Canada.
Kumaraswamy NanthakumarToronto General Hospital, University of Toronto, Toronto, Ontario, Canada.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Despite advancements in postoperative temporary epicardial pacing leads, sensing malfunction can still happen. Oversensing presents as inappropriate inhibition of pacing (a major concern for pacemaker-dependent patients), whereas undersensing may lead to an extremely rare complication of ventricular fibrillation from R on T. The single-lead and dual-lead configurations have key structural differences related to the size of the bipole electrodes and the spacing between them. We assessed how this affects the sensing function. Methods: Five porcine studies were conducted using open chest and Langendorff models. We used 2 pacing wire configurations and compared the sensed electrograms. We compared a newer single-lead configuration (small, closely spaced electrodes) with a dual-lead (large, widely spaced) configuration. The primary outcome was the amplitude of the R wave. Secondary outcomes were the relative size of the T wave and the effect of sampling frequency and low-pass filtering. Results: The sensed QRS was significantly larger in the widely spaced, larger electrodes when compared with closely spaced, smaller electrodes across all sampling frequencies and filter settings (6.9-29.7 mV vs 1.7-8.6 mV, Conclusions: The smaller, closely spaced electrodes detect a relatively small QRS and a larger T wave, leading to a narrower safety window and an increased risk of sensing malfunction (Central Illustration). To avert catastrophic consequences, the electrophysiologic implications of new temporary pacing wires must be considered during postoperative care.

Indexed as

epicardial pacinglead designpostoperative caretemporary pacingundersensingventricular fibrillation