Evidence map›Paper›PMID 41000277›Full record

ArticleJournal of hepatocellular carcinoma2025

A Retrospective Evaluation of Setup Errors Associated with Respiratory Motion Management Techniques in Stereotactic Body Radiation Therapy for Hepatic Malignancies.

Ji-Hua Han, Dong-Cheng He, Xiao-Ye Zhang, Yan Zhang, Jun Hong, Ting-Ting Shi, Zhi-Jian Zhu

Abstract read
In one paragraph

Article in Journal of hepatocellular carcinoma, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Ji-Hua Han *Department of Radiation Oncology, The Affiliated Huaian No.1 People's Hospital of Nanjing Medical University, Huai'an, Jiangsu Province, 223300, People's Republic of China.
Dong-Cheng He *Department of Radiation Oncology, The Affiliated Huaian No.1 People's Hospital of Nanjing Medical University, Huai'an, Jiangsu Province, 223300, People's Republic of China.
Xiao-Ye ZhangDepartment of Radiation Oncology, The Affiliated Huaian No.1 People's Hospital of Nanjing Medical University, Huai'an, Jiangsu Province, 223300, People's Republic of China.
Yan ZhangDepartment of Radiation Oncology, The Affiliated Huaian No.1 People's Hospital of Nanjing Medical University, Huai'an, Jiangsu Province, 223300, People's Republic of China.
Jun HongDepartment of Radiation Oncology, The Affiliated Huaian No.1 People's Hospital of Nanjing Medical University, Huai'an, Jiangsu Province, 223300, People's Republic of China.
Ting-Ting ShiDepartment of Radiation Oncology, The Affiliated Huaian No.1 People's Hospital of Nanjing Medical University, Huai'an, Jiangsu Province, 223300, People's Republic of China.
Zhi-Jian ZhuDepartment of Radiation Oncology, The Affiliated Huaian No.1 People's Hospital of Nanjing Medical University, Huai'an, Jiangsu Province, 223300, People's Republic of China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: This study aimed to evaluate setup errors associated with three respiratory motion management techniques in stereotactic body radiation therapy (SBRT) for individuals with hepatic malignancies. Methods: A retrospective analysis was conducted on data from 55 individuals with hepatic malignancies who underwent SBRT. Respiratory motion was managed using the Active Breathing Coordinator (ABC) in 11 cases, the BodyFIX system in 6 cases, and a thermoplastic body film combined with an airbag in 38 cases. Cone-beam computed tomography (CBCT) was conducted prior to each treatment session and registered with the reference computed tomography (CT) images acquired during the treatment planning phase to quantify setup errors in three dimensions: left-right (LR), superior-inferior (SI), and anterior-posterior (AP). Results: In the LR direction, the BodyFIX group had a 1.07 mm lower setup error than the ABC group, and the airbag group showed a 2.13 mm reduction compared to ABC and 1.06 mm compared to BodyFIX. In the SI direction, BodyFIX showed a 4.66 mm reduction and the airbag group a 5.45 mm reduction versus ABC. In the AP direction, reductions were 1.99 mm for BodyFIX and 2.86 mm for the airbag group compared to ABC. All differences were statistically significant. The airbag group also had relatively small planning target volume (PTV) margins. Conclusion: The airbag-based respiratory motion management technique demonstrated superior positioning accuracy, improved reproducibility, and the potential for PTV margin reduction in SBRT for hepatic malignancies. Further investigations are needed to verify the superiority of this approach in different populations and settings.

Indexed as

hepatic malignanciesmotion managementPTV marginsetup error

Identifiers

PMID41000277
PMCPMC12459612

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.