Evidence map›Paper›PMID 40999022›Full record

ArticleScientific reports2025

Electrophoretic deposition and characterization of CS/nanoHAp/AgNPs composite coatings on titanium from ethanol-based suspensions.

Łukasz Pawłowski, Kaja Kowalczyk, Katarzyna Szczepańska, Katarzyna Galer-Tatarowicz, Aleksandra Mielewczyk-Gryń

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Łukasz PawłowskiDepartment of Biomaterials Technology, Institute of Manufacturing and Materials Technology, Faculty of Mechanical Engineering and Ship Technology, Gdańsk University of Technology, Narutowicza 11/12, Gdańsk, 80-233, Poland. lukasz.pawlowski@pg.edu.pl.
Kaja KowalczykDepartment of Biomaterials Technology, Institute of Manufacturing and Materials Technology, Faculty of Mechanical Engineering and Ship Technology, Gdańsk University of Technology, Narutowicza 11/12, Gdańsk, 80-233, Poland.
Katarzyna SzczepańskaMaritime Institute, Department of Environmental Protection, Gdynia Maritime University, Morska Str. 81-87, Gdynia, 81-225, Poland.
Katarzyna Galer-TatarowiczMaritime Institute, Department of Environmental Protection, Gdynia Maritime University, Morska Str. 81-87, Gdynia, 81-225, Poland.
Aleksandra Mielewczyk-GryńInstitute of Nanotechnology and Materials Engineering, Faculty of Applied Physics and Mathematics, Gdańsk University of Technology, Narutowicza 11/12, Gdańsk, 80-233, Poland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Titanium implants possess bioinert surfaces that limit osseointegration and are prone to bacterial colonization, necessitating functional coatings. This study investigated the electrophoretic deposition (EPD) of composite coatings composed of chitosan (CS), nanohydroxyapatite (nanoHAp), and silver nanoparticles (AgNPs) on grade 2 titanium using an ethanol-acetic acid suspension. The influence of deposition parameters (10-30 V; 3-5 min) on coating microstructure, adhesion, corrosion resistance, wettability, bioactivity, and silver release was systematically examined. The coatings reached a maximum thickness of ~ 7 μm at 30 V/5 min, while the most uniform and adherent coating (class 1, EN ISO 2409) was obtained at 10 V/3 min. Increasing voltage and time produced rougher (Sa up to 1.3 μm) and more porous surfaces, but decreased adhesion. Corrosion resistance improved with coating thickness, with open circuit potentials shifting positively up to + 0.15 V versus the reference electrode. Wettability tests revealed hydrophilic behavior with contact angles of ~ 80°. Bioactivity in simulated body fluid was confirmed by calcium phosphate precipitation on all coated samples, particularly thicker ones. Silver ion release was controlled by deposition parameters, ranging from 0.9 mg/L (10 V/3 min) to 1.8 mg/L (30 V/5 min) after 7 days, indicating a balance between antibacterial functionality and coating integrity. These results demonstrate that ethanol-based EPD can fabricate bioactive, corrosion-resistant CS/nanoHAp/AgNPs coatings with tunable properties. Optimized coatings show potential for biomedical applications, particularly in reducing implant-associated infections while supporting bone integration.

Indexed as

ChitosanCoated Materials, BiocompatibleDurapatiteEthanolMetal NanoparticlesSilverTitaniumCorrosionElectrophoresisSurface PropertiesSuspensionsWettabilityChitosanCoated Materials, BiocompatibleDurapatiteEthanolSilverSuspensionsTitaniumChitosanCoatingsElectrophoretic depositionNanohydroxyapatiteSilver nanoparticles

Identifiers

PMID40999022
PMCPMC12464209

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.