Evidence map›Paper›PMID 40998288›Full record

ArticleIndian pacing and electrophysiology journal

High-density mapping for AVNRT ablation with distorted conduction system anatomy post-ASD device closure-case report.

Subhrajit Lahiri, Maya Baman, Robert M Huibonhoa, Sunita Ferns

Abstract readCase Reports
In one paragraph

Article in Indian pacing and electrophysiology journal. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Subhrajit LahiriDivision of Pediatric Cardiology, Department of Pediatrics, University of Illinois College of Medicine, 1 Illini Drive, Peoria, IL, 61605, USA.
Maya BamanDivision of Pediatric Cardiology, Department of Pediatrics, University of Illinois College of Medicine, 1 Illini Drive, Peoria, IL, 61605, USA.
Robert M HuibonhoaDivision of Pediatric Cardiology, Department of Pediatrics, University of Illinois College of Medicine, 1 Illini Drive, Peoria, IL, 61605, USA.
Sunita FernsDivision of Pediatric Cardiology, Department of Pediatrics, University of Illinois College of Medicine, 1 Illini Drive, Peoria, IL, 61605, USA. Electronic address: sunita@uic.edu.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAtrial septal defects (ASDs) are among the most common congenital heart defects, comprising about 10 % of cases in children. Transcatheter closure of ASDs has become a preferred treatment due to its minimally invasive nature, quicker recovery, and reduced risk compared to surgical closure. Despite its advantages, the procedure carries a risk of post-procedural arrhythmias, particularly bradyarrhythmias and tachyarrhythmias, occurring in approximately 7-10 % of patients. The development of these arrhythmias can be attributed to mechanical interference with conduction tissue or the formation of reentrant circuits around the closure device. These complications can present a challenge for long-term management and require careful monitoring and treatment. CASE SUMMARY: We describe the case of an 8-year-old female who presented with recurrent palpitations after transcatheter closure of two ASDs using a 25 mm Gore Cardioform device. Her initial procedure was uneventful, with complete closure of both defects confirmed by echocardiography. However, one month after the procedure, the patient began experiencing episodes of palpitations and dizziness. Electrocardiographic monitoring revealed regular narrow complex tachycardia, and she was referred for further evaluation. An electrophysiology study confirmed the presence of AV nodal reentrant tachycardia (AVNRT). Detailed mapping revealed significant anatomical distortion of the slow pathway region of the AV node due to proximity to the implanted closure device. Using high-density electroanatomical mapping (HD mapping), we were able to precisely identify the critical pathways for reentry and perform successful slow pathway ablation, eliminating the tachycardia without damaging the closure device or surrounding conduction tissue. The fluoroscopy time was 0.126 mins. DISCUSSION: This case highlights the potential complications that can arise following transcatheter ASD closure, particularly the development of arrhythmias like AVNRT. While arrhythmias following device closure are relatively rare, the mechanical interference caused by the device can result in structural changes to the heart's conduction system, predisposing patients to arrhythmias. In this case, the proximity of the Gore Cardioform device to the slow pathway in the AV node likely contributed to the development of AVNRT, as the device caused localized distortion of the anatomy, facilitating reentrant circuit formation. This case emphasizes the importance of long-term follow-up and the need for advanced mapping techniques in patients undergoing ASD closure who develop post-procedure arrhythmias. High-density electroanatomical mapping, in particular, was essential in this patient, allowing for the precise localization of the arrhythmogenic substrate while avoiding unnecessary damage to the closure device or surrounding healthy tissue. The use of this advanced technology not only improves spatial resolution but also enhances procedural safety by reducing radiation exposure and optimizing outcomes, particularly in pediatric patients with complex congenital heart conditions. Additionally in redo ablations performed after prior procedures at outside centers, high-density mapping has proved valuable in distinguishing patchy low-voltage scar from true slow pathway potentials. This approach enables us to target the functional slow pathway while avoiding ablation of scar tissue.

conclusionIn conclusion, high-density mapping played a crucial role in managing this patient's AVNRT, demonstrating its importance in addressing complex arrhythmias in patients with prior transcatheter ASD closure. Continued advancements in mapping technology will likely further improve the management of arrhythmias associated with congenital heart disease interventions.

Indexed as

ASDAVNRTConduction defectsDevice closureHigh-density mapping

Identifiers

PMID40998288
PMCPMC12717656

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.