Evidence map›Paper›PMID 40995333›Full record

ArticleInternational journal of analytical chemistry2025

Green RP-UPLC Method for Simultaneous Determination of Cyclopentolate and Organic Impurities Using DoE and Sustainability Metrics.

Bandar R Alsehli, Abdullah H Alluhayb, Lateefa A Al-Khateeb, Sayed M Saleh, Ammena Y Binsaleh, Mahmoud A Mohamed

Abstract read
In one paragraph

Article in International journal of analytical chemistry, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Bandar R AlsehliDepartment of Chemistry, Faculty of Science, Taibah University, Al-Madinah Al-Munawarah 30002, Saudi Arabia.ORCID https://orcid.org/0000-0001-8648-6926
Abdullah H AlluhaybDepartment of Chemistry, College of Science, Qassim University, Buraidah 51452, Saudi Arabia.ORCID https://orcid.org/0009-0001-2591-0946
Lateefa A Al-KhateebChemistry Department, Faculty of Science, King Abdulaziz University, P.O. Box 80200, Jeddah 21589, Saudi Arabia.ORCID https://orcid.org/0000-0003-3932-3299
Sayed M SalehDepartment of Chemistry, College of Science, Qassim University, Buraidah 51452, Saudi Arabia.ORCID https://orcid.org/0000-0002-2677-0439
Ammena Y BinsalehDepartment of Pharmacy Practice, College of Pharmacy, Princess Nourah bint Abdulrahman University, P.O. Box 84428, Riyadh 11671, Saudi Arabia.ORCID https://orcid.org/0009-0007-7174-3839
Mahmoud A MohamedHikma Pharmaceutical Company, Beni-Suef 62511, Egypt.ORCID https://orcid.org/0000-0003-3946-5465

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A significant improvement in sustainability and efficiency is achievable through green and white chemistry. As part of this study, sustainability assessment tools were used to assess the environmental impact and practicality of an innovative, straightforward RP-UPLC method to analyze cyclopentolate (CLO) and its organic impurities simultaneously in pure and ophthalmic solutions at the same time. An optimization strategy based on Box-Behnken design was employed to minimize experimental runs while optimizing chromatographic conditions. Using this design, four critical variables were evaluated comprehensively-ethanol percentage in the mobile phase, pH, column temperature, and flow rate-on chromatographic responses such as retention time, resolution between CLO and impurity, and theoretical plate count. As a result of desirable and overlay plots, an optimal condition was selected: 65:25, v/v, ethanol and buffer, pH 4.25, 0.3 mL/min flow rate, and 4°C and 25°C sample and column oven temperatures, respectively, and the main peak retained for a little more than 3 min. The calibration curves for CLO and impurities at concentrations from 5 to 50 μg/mL and 1 to 20 μg/mL showed a correlation value of 0.9998. Recoveries are ±15% of the actual amounts, which is acceptable. RP-UPLC has been extensively designed for the coincidental estimation of anticholinergic drugs and their impurities. A combination of white and green tools was used to assess the method's environmental impact. ICH guidelines have been followed to validate the suggested strategy. This approach offers a reliable, fast, and eco-friendly solution for routine pharmaceutical quality control of anticholinergic agents.

Indexed as

Box–Behnkencyclopentolateorganic impuritiesRP-UPLCsustainability assessment tools

Identifiers

PMID40995333
PMCPMC12457066

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked