Evidence map›Paper›PMID 40993706›Full record

ArticleBMC medical informatics and decision making2025

PilOT-Measure: a mobile 3D depth sensing application to support accurate and efficient clinician-led home-based falls risk assessments.

Zear Ibrahim, Arthur G Money, Anita Atwal, Georgia Spiliotopoulou

Abstract read
In one paragraph

Article in BMC medical informatics and decision making, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Zear IbrahimDepartment of Computer Science, Brunel University London, Uxbridge, UB8 3PH, UK.
Arthur G MoneyDepartment of Computer Science, Brunel University London, Uxbridge, UB8 3PH, UK. arthur.money@brunel.ac.uk.
Anita AtwalDepartment of Childhood and Social Care, University of East London, London, E15 4LZ, UK.
Georgia SpiliotopoulouDepartment of Clinical Sciences, Brunel University London, Uxbridge, UB8 3PH, UK.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAn aging global population, coupled with high levels of assistive equipment abandonment, has propelled increases in falls-related injuries at home. Equipment abandonment occurs, in-part, due to inaccurate measurements of the patient's home taken during the falls risk assessment process. There is an urgent need to explore the value of new digital mobile technologies to help clinicians to take more efficient and effective measurements of patient's home, thereby enhancing the efficacy of falls risk assessments and potentially minimising equipment abandonment.

aimThe aim of this study is to present and evaluate the accuracy and efficiency of PilOT-Measure, a digital mobile 3D depth-sensor-enabled measurement guidance application for use by clinicians carrying out falls risk assessments.

methodsTwenty-one trainee and registered Occupational Therapists took part in this repeated-measures, mixed methods study to evaluate measurement accuracy, task completion time, and overall system usability and user perceptions of the application.

resultsFor measurement accuracy, PilOT-Measure outperformed current state of the art handheld tape measure and paper-based measurement guidance booklet. For accuracy consistency, the handheld tape measure and booklet was more consistently accurate for six out of 11 cases. However, PilOT-Measure tended to facilitate significantly faster task completion times, suggesting potential task efficiency benefits. In terms of usability, participants favoured PilOT-Measure and saw potential to reduce administrative tasks and support joint decision-making. Concerns about marker placement on reflective surfaces and patient privacy were noted.

conclusionsThis study highlights the positive role that mobile depth-sensing technologies can potentially play in improving the efficiency and accuracy of falls risk assessments, hence, reducing levels of equipment abandonment and falls related injuries at home. Future work will focus on improving marker placement, measurement accuracy, and accuracy consistency and explore the potential of using PilOT-Measure as a falls risk patient self-assessment tool.

Indexed as

Accidental FallsMobile ApplicationsAdultFemaleHumansMalePilot ProjectsRisk Assessment3D mobile application3D visualisationAugmented realityDepth sensingFalls preventionFalls risk factorsMeasurementOccupational therapyTechnology for healthVirtual reality

Identifiers

PMID40993706
PMCPMC12462305

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.