Reduction of metallic artifacts from the novel leadless pacemaker using single-energy metal artifact reduction algorithm in coronary CT angiography.

Yahui Hu, Ying Chen, Jianjun Huo, Linxin Zhang, Yan Li, Qian Liu, Yaohui Yu, Haicheng Qi, Zicheng Zhao, Jiaojiao Zhang and 2 more

Abstract read
In one paragraph

Article in BMC medical imaging, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Yahui Hu *Department of Pain Medicine, Midong District Hospital of Traditional Chinese Medicine, No. 1055, Fuqian Middle Road, Midong District, Urumqi City, Xinjiang, 831400, China.
Ying Chen *Imaging Center, The First Affiliated Hospital of Xinjiang Medical University, No. 137, Liyushan SouthRoad, Urumqi, Xinjiang, 830011, China.
Jianjun HuoDepartment of Surgery, Horgos Municipal People's Hospital, 12 Ping'an Road, Horgos City, Xinjiang, 835000, China.
Linxin ZhangImaging Center, The First Affiliated Hospital of Xinjiang Medical University, No. 137, Liyushan SouthRoad, Urumqi, Xinjiang, 830011, China.
Yan LiImaging Center, The First Affiliated Hospital of Xinjiang Medical University, No. 137, Liyushan SouthRoad, Urumqi, Xinjiang, 830011, China.
Qian LiuImaging Center, The First Affiliated Hospital of Xinjiang Medical University, No. 137, Liyushan SouthRoad, Urumqi, Xinjiang, 830011, China.
Yaohui YuImaging Center, The First Affiliated Hospital of Xinjiang Medical University, No. 137, Liyushan SouthRoad, Urumqi, Xinjiang, 830011, China.
Haicheng QiImaging Center, The First Affiliated Hospital of Xinjiang Medical University, No. 137, Liyushan SouthRoad, Urumqi, Xinjiang, 830011, China.
Zicheng ZhaoCT Business Unit, Canon Medical Systems (China), Beijing, China.
Jiaojiao ZhangCT Business Unit, Canon Medical Systems (China), Beijing, China.
Min XuCT Business Unit, Canon Medical Systems (China), Beijing, China.
Yan XingImaging Center, The First Affiliated Hospital of Xinjiang Medical University, No. 137, Liyushan SouthRoad, Urumqi, Xinjiang, 830011, China. xingyanzwb@sina.com.

Funding

National Natural Science Foundation of China 82160334Tianshan Talent Training Program TSYC202301B009
6 · The paper itself

Abstract

objectiveTo evaluate the efficacy of single-energy metal artifact reduction (SEMAR) algorithm in removing metallic artifacts for patients with novel leadless pacemakers (PMs) compared to those with conventional transvenous PMs.

methods30 patients with transvenous PMs and 30 patients with leadless PMs having coronary CT angiography (CCTA) were included. Images were reconstructed using two methods: a conventional hybrid-iterative reconstruction (HIR) algorithm separately, and the HIR combined with SEMAR algorithm. The artifact index (AI) was calculated for both datasets to quantitatively assess the artifact reduction. Two senior radiologists independently scored the artifact extent and diagnostic confidence of surrounding tissues. The position of artifacts-impaired tissues was also visually evaluated as follows: non-impaired, impaired, and equivocal. The study was ethics committee-approved.

resultsThe leadless PM

conclusionsSEMAR provides effective reduction of metallic artifacts from both types of cardiac PMs. The artifact-impaired tissues are fewer on leadless PMs, resulting in an enhanced diagnostic confidence in the surrounding tissues.

Indexed as

AlgorithmsArtifactsComputed Tomography AngiographyCoronary AngiographyPacemaker, ArtificialAgedAged, 80 and overFemaleHumansMaleMetalsMiddle AgedRadiographic Image Interpretation, Computer-AssistedMetalsArtifactsCoronary CT angiographyLeadless pacemakerTomography, x-ray computed

Identifiers

PMID40993584
PMCPMC12462349

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.