ArticleThe AAPS journal2025
Validation of a Göttingen Minipig Gene Therapy Biodistribution Assay for AVGN7 Using Droplet Digital Polymerase Chain Reaction.
Article in The AAPS journal, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
Minipig models are rapidly gaining popularity in gene therapy preclinical studies. This includes biodistribution studies that are required by regulatory agencies, but are poorly described in the literature. This is particularly true for ddPCR assays with enhanced sensitivity over traditional "real-time" PCR. We, therefore, validated a novel duplex ddPCR assay for quantifying AVGN7, an AAV gene therapeutic featuring a codon-optimized human Smad7 gene and the porcine RPP30 reference gene, in Göttingen minipig tissues. The DNA extraction methods were optimized to ensure maximum recovery of target gene. Validation parameters included accuracy and precision, limit of detection, ruggedness/robustness, selectivity, recovery, dilutional linearity and stability. The assay was sensitive to 10 cp/µg gDNA while intra- and inter-accuracy and precision were demonstrated for the dynamic range of 25,000-5 cp/µL where the inter-assay total error was ≤ 35.5% for AVGN7 and ≤ 4.3% for RPP30. Moreover, ruggedness was assessed over time using multiple analysts, instruments and reagent lots, demonstrating high reliability and reproducibility. Linearity was established across 1,000-fold dilutions and stability after 6 freeze-thaw cycles and 24 h at room temperature. Selectivity was evaluated in unspiked and post-spiked samples using multiple lots of different tissue matrices. High recovery of AVGN7 during nucleic acid extraction was also demonstrated for all tissues. These data not only validate the assay for tracking and quantifying AVGN7 in preclinical studies with Göttingen minipigs, but additionally address challenges of using pig models in general while providing a procedural road map for developing other AAV biodistribution assays.
Indexed as
Identifiers
40993346What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.