Evidence map›Paper›PMID 40991687›Full record

ArticleScience advances2025

A microneedle device for rapid dermal interstitial fluid sampling.

Andy H Hung, Netra U Kamat, Abel Bermudez, Stephanie M Boczek, Fernando J Garcia-Marqués, Yee Lin Tan, Jihyun Luna Hwang, Prima Dewi Sinawang, Dan Ilyin, Gunilla B Jacobson and 4 more

Abstract read
In one paragraph

Article in Science advances, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Review
  2. Article
  3. Review
  4. Review
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

14 authors.

Andy H HungDepartment of Radiology, School of Medicine, Stanford University, CA 94305, USA.ORCID 0000-0003-0182-5648
Netra U KamatDepartment of Bioengineering, Stanford University, CA 94305, USA.ORCID 0000-0003-0277-6120
Abel BermudezDepartment of Radiology, School of Medicine, Stanford University, CA 94305, USA.ORCID 0009-0002-3235-5538
Stephanie M BoczekDepartment of Chemical Engineering, Stanford University, CA 94305, USA.ORCID 0009-0007-2963-9675
Fernando J Garcia-MarquésDepartment of Radiology, School of Medicine, Stanford University, CA 94305, USA.ORCID 0000-0002-2105-2905
Yee Lin TanDepartment of Materials Science and Engineering, Stanford University, CA 94305, USA.
Jihyun Luna HwangDepartment of Chemical Engineering, Stanford University, CA 94305, USA.ORCID 0009-0003-0067-8444
Prima Dewi SinawangCanary Center, School of Medicine, Stanford University, CA 94305, USA.ORCID 0000-0001-8460-3260
Dan IlyinDepartment of Mechanical Engineering, Stanford University, CA 94305, USA.
Gunilla B JacobsonDepartment of Radiology, School of Medicine, Stanford University, CA 94305, USA.ORCID 0000-0001-6860-5258
Utkan DemirciDepartment of Radiology, School of Medicine, Stanford University, CA 94305, USA.ORCID 0000-0003-2784-1590
Steven P PoplackDepartment of Radiology, School of Medicine, Stanford University, CA 94305, USA.ORCID 0000-0002-5026-371X
Sharon J PitteriDepartment of Radiology, School of Medicine, Stanford University, CA 94305, USA.ORCID 0000-0002-3119-873X
Joseph M DeSimoneDepartment of Radiology, School of Medicine, Stanford University, CA 94305, USA.ORCID 0000-0002-1764-8634

Funding

NCI NIH HHS T32CA00969531
6 · The paper itself

Abstract

Dermal interstitial fluid (ISF) offers a promising alternative to invasive blood tests and opportunities for skin diagnostics. Progress in both the understanding and adoption of ISF tests is hindered by sampling challenges, including lengthy collection times, non-negligible failure rates, variable collection volumes, and inconsistent bioanalyte levels. The causes of many of these issues are not well understood. We demonstrate a microneedle device that is several times faster than state of the art, collecting an average of 15.5 mg of ISF in 5 minutes in humans with near-zero failure rate. This improvement was achieved by designing the spatial pressure gradient driving ISF flow. The influence of penetration depth, collection time, pressure, and age on ISF collection was elucidated, with Darcy's law explaining multiple observations. A data-driven acceptance criterion of <1% blood contamination for ISF is proposed. The device and findings presented will empower researchers to better conduct robust studies in the development of ISF diagnostics.

Indexed as

Extracellular FluidNeedlesSkinSpecimen HandlingHumans

Identifiers

PMID40991687
PMCPMC12459406

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.