Evidence map›Paper›PMID 40991626›Full record

ArticlePLOS digital health2025

Detection of pneumonia in children through chest radiographs using artificial intelligence in a low-resource setting: A pilot study.

Taofeeq Oluwatosin Togunwa, Abdulhammed Opeyemi Babatunde, Oluwatosin Ebunoluwa Fatade, Richard Olatunji, Godwin Ogbole, Adegoke Falade

Abstract read
In one paragraph

Article in PLOS digital health, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Review
  2. Review
  3. Article
  4. Review
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Taofeeq Oluwatosin TogunwaCollege of Medicine, University of Ibadan, Ibadan, Nigeria.ORCID https://orcid.org/0009-0000-2786-7315
Abdulhammed Opeyemi BabatundeCollege of Medicine, University of Ibadan, Ibadan, Nigeria.
Oluwatosin Ebunoluwa FatadeDepartment of Radiology, University College Hospital, Ibadan, Nigeria.
Richard OlatunjiDepartment of Radiology, University College Hospital, Ibadan, Nigeria.
Godwin OgboleDepartment of Radiology, University College Hospital, Ibadan, Nigeria.
Adegoke FaladeDepartment of Paediatrics, University College Hospital, Ibadan, Nigeria.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Pneumonia is a leading cause of death among children under 5 years in low-and-middle-income-countries (LMICs), causing an estimated 700,000 deaths annually. This burden is compounded by limited diagnostic imaging expertise. Artificial intelligence (AI) has potential to improve pneumonia diagnosis from chest radiographs (CXRs) through enhanced accuracy and faster diagnostic time. However, most AI models lack validation on prospective clinical data from LMICs, limiting their real-world applicability. This study aims to develop and validate an AI model for childhood pneumonia detection using Nigerian CXR data. In a multi-center cross-sectional study in Ibadan, Nigeria, CXRs were prospectively collected from University College Hospital (a tertiary hospital) and Rainbow-Scans (a private diagnostic center) radiology departments via cluster sampling (November 2023-August 2024). An AI model was developed on open-source paediatric CXR dataset from the USA, to classify the local prospective CXRs as either normal or pneumonia. Two blinded radiologists provided consensus classification as the reference standard. The model's accuracy, precision, recall, F1-score, and area-under-the-curve (AUC) were evaluated. The AI model was developed on 5,232 open-source paediatric CXRs, divided into training (1,349 normal, 3,883 pneumonia) and internal test (234 normal, 390 pneumonia) sets, and externally tested on 190 radiologist-labeled Nigerian CXRs (93 normal, 97 pneumonia). The model achieved 86% accuracy, 0.83 precision, 0.98 recall, 0.79 F1-score, and 0.93 AUC on the internal test, and 58% accuracy, 0.62 precision, 0.48 recall, 0.68 F1-score, and 0.65 AUC on the external test. This study illustrates AI's potential for childhood pneumonia diagnosis but reveals challenges when applied across diverse healthcare environments, as revealed by discrepancies between internal and external evaluations. This performance gap likely stems from differences in imaging protocols/equipment between LMICs and high-income settings. Hence, public health priority should be developing robust, locally relevant datasets in Africa to facilitate sustainable and independent AI development within African healthcare.

Identifiers

PMID40991626
PMCPMC12459801

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.