Evidence map›Paper›PMID 40990226›Full record

ArticleClinical physiology and functional imaging2025

Reproducibility of diastolic function parameters in repeated ECG-gated SPECT myocardial perfusion imaging and echocardiography.

Aaro Krohns, Tomi P Laitinen, Tiina M Laitinen, Saara Sillanmäki

Abstract readComparative Study
In one paragraph

Article in Clinical physiology and functional imaging, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Aaro KrohnsUniversity of Eastern Finland, Kuopio, Finland.
Tomi P LaitinenDiagnostic Imaging Center, Kuopio University Hospital, Kuopio, Finland.
Tiina M LaitinenDiagnostic Imaging Center, Kuopio University Hospital, Kuopio, Finland.
Saara SillanmäkiDiagnostic Imaging Center, Kuopio University Hospital, Kuopio, Finland.ORCID https://orcid.org/0000-0002-8130-3219

Funding

This study was financially supported by the Finnish Foundation for Cardiovascular Research (10.11.2020 for T.P.L.). S.S. has achieved funding from the Research Committee of the Kuopio University Hospital Catchment Area for State Research Funding (5063586).
6 · The paper itself

Abstract

objectiveTo study the reproducibility of diastolic function parameters from myocardial perfusion imaging (MPI) using ECG-gated single photon emission computed tomography (SPECT), and echocardiography in repeated imaging.

methodsWe studied the reproducibility of MPI diastolic function parameters peak-filling rate (PFR) and time to peak filling (TTPF) as well as echocardiographic parameters E/A, E/e', and E-wave deceleration time (DT). The study population consisted of 21 patients who underwent routine MPI with repeated rest acquisition and echocardiography. In a test-retest setting, appropriate diastolic measures were successfully obtained using SPECT in 20 patients, with E/A measured in 18, E/e' in 17, and DT in 16 patients.

resultsWe found that PFR was well reproducible with the intraclass correlation coefficient (ICC) 0.887, and coefficient of variation (CV%) 10.5. However, TTPF was poorly reproducible (ICC 0.012, and CV% 17.5). E/A was highly reproducible (ICC 0.963, and CV% 12.5). Decent reproducibility was observed for E/e' (ICC 0.809, and CV% 18.6) and DT (ICC 0.833, and CV% 12.0). We further studied the correlation between these parameters. PFR (EDV/s) had negative correlation with DT (r = -0.538, p = 0.039) and E/A had positive with E/é (r = 0.689, p = 0.002). No other significant correlations were observed (p > 0.05 for all). We also examined how parameters classified patients as normal or abnormal regarding the diastolic function. E/A and E/e´, as well as E/A and PFR showed similar classifications in 88% of cases, with a Kappa value of 0.433, p = 0.074 for both.

conclusionsPFR obtained from repeated SPECT studies, along with the E/A ratio, is highly reproducible.

Indexed as

Cardiac-Gated Single-Photon Emission Computer-Assisted TomographyEchocardiographyElectrocardiographyMyocardial Perfusion ImagingVentricular Dysfunction, LeftVentricular Function, LeftAgedDiastoleFemaleHumansMaleMiddle AgedObserver VariationPredictive Value of TestsReproducibility of ResultsTime Factorsdiastolic functionechocardiographymyocardial perfusion imagingpeak‐filling ratereproducibilitysingle‐photon emission computed tomography

Identifiers

PMID40990226
PMCPMC12459082

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.