ArticleIEEE robotics and automation letters2024
Universal Actuation Module and Kinematic Model for Heart Valve Interventional Catheter Robotization.
Article in IEEE robotics and automation letters, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- MitraNav: Design and Modeling of a Robotic System for Transseptal Mitral Valve Replacement with Dock Catheter Task-Space Control.Annals of biomedical engineering · 2026Article
- Development and Evaluation of a Robotic System for Safe Cardiac Sheath Delivery.IEEE transactions on bio-medical engineering · 2025Article
- Towards autonomous robot-assisted transcatheter heart valve implantation: in vivo teleoperation and phantom validation of AI-guided positioning.Frontiers in robotics and AI · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors.
Funding
Abstract
Catheters have been widely used to deal with heart valve diseases. However, the diversity in handle structures and bending curvatures imposes significant complexities in safe delivery and positioning. In this work, we designed a module for single knob actuation assembled coaxially on the catheter handle, composed of a chuck for universal clamping of diameters from 15 to 45 mm and a position-adjustable shaft to accommodate various spacing between knobs. In addition, we proposed a two-curvature with pseudo joints (TC-PJ) model for bending control of bendable sections (BSs) in catheters. The verification was decoupled into two steps based on the other three deformation patterns. Firstly, comparing the two-curvature (TC) model with pseudo-rigid-body (PRB), constant curvature (CC), and Euler spiral (ES) models to simulate planar bending and elongation, the results showed a more accurate shape representation. Then, five distinct catheters were employed to test the clamping universality of the module and tip positioning precision of the TC-PJ model which took torsion and shear strain into consideration. The root-mean-square error (RMSE) and the standard deviation (SD) of tip position and direction were analysed. Results indicated the module's suitability for clamping these catheters, with the large guide sheath exhibiting minimal position RMSE (SD) of around 0.10 (0.051) mm and 0.049 (2.15) degrees, while the puncture catheter demonstrated the highest position and direction RMSE (SD) extending to about 1.16 (0.53) mm and 0.70 (31.33) degrees, primarily attributed to the coupling of two sequential bendable components. Overall, the proposed actuation module and kinematic model showed the ability of universal manipulation and an average tip position and direction RMSE of 0.65 mm and 0.23 degrees in free space.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials