ArticlePloS one2025

Validity of four low-cost smartwatches in estimating energy expenditure during cycling in Chinese untrained women.

Yongfu Liu, Fei Liu, Wenjun Yu, Yuxin Xiao, Di Liu, Zhi Li, Weiwei Chen, Feng Gao, Shenglong Le

Abstract read
In one paragraph

Article in PloS one, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Yongfu LiuDepartment of Physical Therapy, Taihe Hospital, Hubei University of Medicine, Shiyan, Hubei, China.ORCID 0009-0006-7935-7193
Fei LiuDepartment of Physical Therapy, Taihe Hospital, Hubei University of Medicine, Shiyan, Hubei, China.
Wenjun YuDepartment of Physical Therapy, Taihe Hospital, Hubei University of Medicine, Shiyan, Hubei, China.
Yuxin XiaoDepartment of Physical Therapy, Taihe Hospital, Hubei University of Medicine, Shiyan, Hubei, China.
Di LiuDepartment of Physical Therapy, Taihe Hospital, Hubei University of Medicine, Shiyan, Hubei, China.
Zhi LiCenter for Diabetes Rehabilitation Research, Taihe Hospital, Hubei University of Medicine, Shiyan, Hubei, China.
Weiwei ChenDepartment of Physical Education, Shanghai Jiao Tong University, Shanghai, China.
Feng GaoDepartment of Physical Therapy, Taihe Hospital, Hubei University of Medicine, Shiyan, Hubei, China.
Shenglong LeDepartment of Physical Therapy, Taihe Hospital, Hubei University of Medicine, Shiyan, Hubei, China.ORCID 0000-0003-0925-9660

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Wrist-worn activity monitors, such as smartwatches, are frequently used to monitor energy expenditure (EE) of physical activity, but there is a high degree of heterogeneity in their accuracy. The purpose of this study was to evaluate the validity of four affordable, low-price smartwatches, including HONOR Band 7 (HNB7), HUAWEI Band 8 (HWB8), XIAOMI Smart Band 8 (XMB8), and KEEP Smart Band B4 Lite (KPB4L), for estimating EE during ergometer cycling in untrained Chinese women. Twenty Chinese women who exercised ≤3 times per week simultaneously wore two smartwatches, randomly assigned to each wrist, during cycling at 30W, 40W, 50W and 60W on the ergometer. As the golden standard, indirect calorimetry (CORTEX METAMAX 3B, MM3B) was used to evaluate EE at the same time. For all loads, EE values were significantly overestimated by XMB8 and KPB4L, compared to the golden standard (all p < 0.001), but not by HNB7 and HWB8. The mean absolute percentage error (MAPE) was 49.5-57.4% for the KPB4L, 30.5-41.0% for the XMB8, 12.5-18.6% for the HWB8, and 15.0-23.0% for the HNB7, respectively. A lower MAPE value indicates that smartwatch estimates are closer to the golden standard. Bland-Altman plots indicated a trend of increasing positive bias as EE increased across all devices, with the XMB8 and KPB4L showing this pattern most clearly. The results clearly show that although HNB7 and HWB8 demonstrated moderate accuracy, there were significant differences in EE estimation accuracy across the tested devices. These findings suggest caution in using low-price smartwatches for energy balance management in untrained female populations. However, the findings of this study are subject to limitations, such as a small and homogeneous sample size, and the occasional missing of data across multiple load levels. Future studies should increase the sample size and include more diverse participants to validate these findings.

Indexed as

BicyclingEnergy MetabolismWearable Electronic DevicesAdultCalorimetry, IndirectChinaEast Asian PeopleExerciseFemaleHumansYoung Adult

Identifiers

PMID40986546
PMCPMC12456781

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.