Evidence map›Paper›PMID 40986085›Full record

ArticleEuropean journal of trauma and emergency surgery : official publication of the European Trauma Society2025

High-Accuracy reduction of comminuted diaphyseal femur fractures using on-site 3-D-printed guides.

Sophie C Eberlein, Samuel F Schaible, Frank M Klenke, Andreas Hecker

Abstract read
In one paragraph

Article in European journal of trauma and emergency surgery : official publication of the European Trauma Society, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Sophie C EberleinDepartment of Orthopedic Surgery and Traumatology, University Hospital Bern, Inselspital, University of Bern, Bern, Switzerland. sophie.eberlein@insel.ch.
Samuel F SchaibleDepartment of Orthopedic Surgery and Traumatology, University Hospital Bern, Inselspital, University of Bern, Bern, Switzerland.
Frank M KlenkeDepartment of Orthopedic Surgery and Traumatology, University Hospital Bern, Inselspital, University of Bern, Bern, Switzerland.
Andreas HeckerDepartment of Orthopedic Surgery and Traumatology, University Hospital Bern, Inselspital, University of Bern, Bern, Switzerland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposePersistent malalignment-especially rotational error-after fixation of comminuted femoral shaft fractures compromises function and often necessitates revision surgery. This study evaluated whether point-of-care, patient-specific three-dimensional printed reduction guides can reproducibly restore native femoral length, coronal-sagittal alignment and axial rotation in a cadaveric model simulating highly comminuted shaft fractures.

methodsTen freshfrozen human legs were CTscanned, virtually reduced, and fitted with patientspecific guides printed in a sterilizable medical resin. A 2 cm midshaft segment was resected to simulate a comminuted fracture. Each construct was reduced with the guides and stabilized with a locking compression plate. Postoperative CT volumes were superimposed to the preoperative plan to quantify absolute deviations in length, coronal (varus/valgus), sagittal (procurvatum/recurvatum), and axial rotation.

resultsAll reductions were completed without technical difficulty. Mean ± SD absolute errors were 1.50 ± 1.08 mm in length, 0.92 ± 0.41° in the coronal plane, 1.33 ± 1.34° in the sagittal plane, and 4.33 ± 1.88° in rotation-well within acceptable clinical limits.

conclusionOn‑site printed, patient‑specific guides achieved high accuracy in a comminuted femoral fracture model. Clinical studies are required to determine whether this accuracy translates into improved patient outcomes.

Indexed as

Femoral FracturesFracture Fixation, InternalFractures, ComminutedPrinting, Three-DimensionalSurgery, Computer-AssistedBone PlatesCadaverDiaphysesHumansTomography, X-Ray Computed3-D printingCadaveric studyFemoral shaft fractureOrthopedic traumaPatient-specific reduction guideRotational malalignment

Identifiers

PMID40986085
PMCPMC12457565

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.