ArticleTranslational vision science & technology2025
Using Artificial Intelligence to Predict Implantable Collamer Lens Vault: A Low Parameter-Dependent Model for Better Surgical Outcomes.
Article in Translational vision science & technology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Retrospective Validation of an AI Based Tool for Vault Prediction After Implantable Collamer Lens Surgery for High Myopia.Clinical ophthalmology (Auckland, N.Z.) · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Purpose: The purpose of this study was to predict the vault of implantable collamer lens using artificial intelligence (AI) and interpret the contributions of each parameter. Methods: Extreme Gradient Boosting (XGBoost), a machine learning algorithm, was applied to construct a vault prediction model. The dataset included 247 eyes from Peking University Third Hospital, split into training and test sets (4:1), plus 50 eyes from Beau Care Clinic for external validation. The model was trained and tested by samples with missing and anomalous values to enhance its robustness. Model performance was assessed using mean absolute error (MAE), root mean square error (RMSE), and median absolute error (MedAE). SHapley Additive exPlanations (SHAP) was used to interpret the model's predictions. Results: We found weak linear correlation between preoperative parameters and vaults (all |r| ≤ 0.30). Therefore, a nonlinear model was constructed. It achieved the following performance on the test set: MAE = 117.85 µm, RMSE = 146.92 µm, and MedAE = 108.94 µm. On the external validation set, corresponding metrics were 130.99 µm, 154.24 µm, and 116.51 µm, respectively. SHAP revealed horizontal sulcus-to-sulcus distance (STS), horizontal compression (HC), anterior chamber depth (ACD), and white-to-white distance (WTW) had positive influences on the vault, whereas lens thickness (LT) and crystalline lens rise (CLR) had negative effects. Female subjects also tended to have higher vaults. Conclusions: A low parameter-dependent implantable collamer lens (ICL) vault prediction model which exhibits great robustness was constructed. Translational Relevance: The use of AI to predict the vault after ICL implantation can reduce the abnormal postoperative vault and improve the safety of ICL implantation.