Attitudes of Anaesthesiology Specialists and Residents Toward Hemodynamic Monitoring: A National Survey Study.

Gamze Talih, Aslıhan Aykut, Burhan Dost, Emre Sertaç Bingül, Başak Akça, Muhammed Enes Aydın, Z Aslı Demir, Ümit Karadeniz, Ali Fuat Erdem

Abstract read
In one paragraph

Article in Turkish journal of anaesthesiology and reanimation, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Make the Invisible Visible: Abandoning Comfortable Blindness in Anaesthesia.Turkish journal of anaesthesiology and reanimation · 2026
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Gamze TalihErciyes University Faculty of Medicine, Department of Anaesthesiology and Reanimation, Kayseri, Türkiye.ORCID 0000-0003-4743-9734
Aslıhan AykutAnkara Bilkent City Hospital, Clinic of Anaesthesiology and Reanimation, Ankara, Türkiye.ORCID 0000-0003-0382-3494
Burhan DostOndokuz Mayıs University Faculty of Medicine, Department of Anaesthesiology and Reanimation, Samsun, Türkiye.ORCID 0000-0002-4562-1172
Emre Sertaç Bingülİstanbul University, İstanbul Faculty of Medicine, Department of Anaesthesiology and Reanimation, İstanbul, Türkiye.ORCID 0000-0002-8662-5380
Başak AkçaHacettepe University Faculty of Medicine, Department of Anaesthesiology and Reanimation, Ankara, Türkiye.ORCID 0000-0003-4069-2462
Muhammed Enes AydınAtatürk University Faculty of Medicine, Department of Anaesthesiology and Reanimation, Erzurum, Türkiye.ORCID 0000-0001-8491-6566
Z Aslı DemirAnkara Bilkent City Hospital, Clinic of Anaesthesiology and Reanimation, Ankara, Türkiye.ORCID 0000-0003-3053-0443
Ümit KaradenizAnkara Bilkent City Hospital, Clinic of Anaesthesiology and Reanimation, Ankara, Türkiye.ORCID 0000-0002-0067-6938
Ali Fuat ErdemSakarya University Faculty of Medicine, Department of Anaesthesiology and Reanimation, Sakarya, Türkiye.ORCID 0000-0001-6994-397X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: This descriptive survey study aims to evaluate the knowledge, attitudes, and practices of anaesthesiology specialists and residents in Türkiye regarding advanced hemodynamic monitoring in high-risk surgical patients. Methods: The survey, comprising 25 questions, was distributed to 960 anaesthesia professionals, with 713 completing the questionnaire. Results: The study reveals that while invasive blood pressure monitoring is widely used (96.3%), the adoption of advanced hemodynamic monitoring techniques, such as cardiac output monitoring, remains limited (12.6%). For awake high-risk surgical patients under regional anaesthesia, a significant proportion of respondents (15.1% and 37.1%) considered non-invasive blood pressure monitoring to be insufficient. Additionally, 41.1% of participants believed that stroke volume variation, pulse pressure variation, and systolic pressure variation parameters could be used to assess fluid deficits in awake patients. Conclusion: High costs, technical complexity, and lack of training are identified as major barriers. The findings highlight the need for enhanced educational programs and practical training to improve the utilization of advanced hemodynamic monitoring, ultimately aiming to reduce perioperative morbidity and mortality. The study underscores the importance of integrating advanced hemodynamic monitoring into routine clinical practice and suggests the development of nationwide algorithms to standardize practices.

Indexed as

Advanced hemodynamic monitoringfluid responsivenessgoal-directed therapyhigh-risk surgical patientssurvey