Evidence map›Paper›PMID 40975487›Full record

ArticleExperimental eye research2025

Examining murine eye length asymmetry with spectral domain optical coherence tomography.

Linjiang Lou, Katelyn M Hall, Machelle T Pardue

Abstract read
In one paragraph

Article in Experimental eye research, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Linjiang LouDepartment of Ophthalmology, Emory University School of Medicine, 1365B Clifton Rd NE, Atlanta, GA, 30322, United States.
Katelyn M HallDepartment of Biomedical Engineering, Georgia Institute of Technology and Emory University, 313 Ferst Dr, Atlanta, GA, 30332, United States.
Machelle T PardueDepartment of Ophthalmology, Emory University School of Medicine, 1365B Clifton Rd NE, Atlanta, GA, 30322, United States; Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, 313 Ferst Dr, Atlanta, GA, 30332, United States; Joseph Maxwell Cleland Atlanta VA Medical Center, 1670 Clairmont Rd, Decatur, GA, 30033, United States. Electronic address: mpardue@emory.edu.

Funding

P30-Core Grant for Vision Research Core CP30EY006360 · NEI · EMORY UNIVERSITY · PI BOATRIGHT, JEFFREY H · 1986 to 2025
$15.3M
Retinal Mechanisms of Refractive DevelopmentR01EY016435 · NEI · GEORGIA INSTITUTE OF TECHNOLOGY · PI Machelle T. Pardue · 2009 to 2026
$5.4M
VIsion Science Training in AtlantaT32EY007092 · NEI · EMORY UNIVERSITY · PI Machelle T. Pardue · 1985 to 2026
$4.6M
Mechanisms of axial elongation in myopiaR01EY033361 · NEI · GEORGIA INSTITUTE OF TECHNOLOGY · PI C ROSS ETHIER, MAUREEN A KANE · 2022 to 2026
$2.9M
NEI NIH HHS P30 EY006360NEI NIH HHS R01 EY016435NEI NIH HHS R01 EY033361NEI NIH HHS T32 EY007092RRD VA IK6 RX003134
6 · The paper itself

Abstract

The mouse is an increasingly popular model for examining refractive development, however measuring axial length in the small mouse eye is challenging. We measured ocular axial dimensions with spectral domain optical coherence tomography (SD-OCT) and examined how ocular dimensions vary with alignment of the SD-OCT system in a mouse model of lens-induced myopia. Refractive error, corneal radius of curvature, and ocular dimensions were measured in C57BL/6J mice from P25 to P46. Mice received monocular lens treatment with either a -10D (n = 14) or -30D lens (n = 13) at P28 or had no lens treatment (n = 14). OCT images were taken at different eccentricities in the temporal, nasal, inferior, and superior quadrants of the eye. Axial length, vitreous chamber depth (VCD), and anterior chamber depth decreased with increasing eccentricity (P < 0.001), whereas lens thickness increased with greater eccentricity (P < 0.001). Axial length and VCD were longer in the superior and temporal quadrants compared to the nasal and inferior quadrants (P < 0.001). The -30D lens induced a greater myopic shift compared to the -10D lens (P < 0.001). Both lenses induced a steeper corneal curvature compared to the contralateral eye (P < 0.01). There were no significant differences in ocular dimensions between lens treatment groups, quadrants, or eccentricities (P > 0.05). Changes in corneal radius of curvature could predict the myopic shift observed with lens treatment. Findings suggest that there are significant differences in axial length measurements depending on the alignment of the OCT system. Thus, consistent alignment to the same region is important for accurate comparison of axial length in mouse eyes with experimental myopia.

Indexed as

Axial Length, EyeCorneaMyopiaTomography, Optical CoherenceAnimalsAnterior ChamberDisease Models, AnimalMiceMice, Inbred C57BLRefraction, OcularAxial lengthMouseMyopiaOCTOptical coherence tomography

Identifiers

PMID40975487
PMCPMC12503763

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.