ArticleMedical science monitor : international medical journal of experimental and clinical research2025
Effects of Injectable Platelet-Rich Fibrin on the Osseointegration of Dental Implants.
Article in Medical science monitor : international medical journal of experimental and clinical research, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Platelet-Rich Fibrin and Its Derivatives as Adjuncts to Dental Implant Osseointegration: A Scoping Review.International journal of dentistry · 2026Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
BACKGROUND Many methods are used to increase the osseointegration of dental implants. This study aimed to evaluate the effect of injectable platelet-rich fibrin (i-PRF) on the osseointegration of dental implants in 20 patients, as measured by resonance frequency analysis. MATERIAL AND METHODS The study included 20 patients, with each patient receiving 2 SLA implants. After preparing the 2 implant sockets in each patient, one socket was randomly selected and irrigated with i-PRF before implant placement, while the other socket was left untreated. Implant stability was evaluated using a frequency analysis device at a 3-month evaluation. RESULTS The initial implant stability quotient (ISQ) values of the implants in the the test group (i-PRF+) averaged 68.875±9.571, increasing to 74.237±8.283 after 3 months. In the control group (i-PRF-), the initial ISQ values averaged 73.275±7.699 and measured 73.662±8.089 after 3 months. The ISQ values of women in the i-PRF+ group were significantly higher than those of men (P=0.004), whereas no statistically significant difference was found between male and female patients in the i-PRF- group (P=0.399). No statistically significant difference was found in ISQ values based on bone density in either the test or control groups (test group, P=0.109; control group, P=0.430). CONCLUSIONS Implants treated with i-PRF demonstrated significantly higher stability values in resonance frequency evaluations compared to untreated implants. Additionally, while i-PRF application resulted in a significantly greater increase in stability in women than in men, bone density did not have an effect on stability.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.