Evidence map›Paper›PMID 40971087›Full record

ArticleCurrent medical science2025

Effect of Screw Distribution on Stability and Interfragmentary Strain of Lower Tibial Fractures: A Finite Element Analysis.

Huan Su, Huan Xiao, Jian-Jun Zhou, Fang Lei, Liang Liang, De-Wei Wang

Abstract read
In one paragraph

Article in Current medical science, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Huan SuDepartment of Bone and Joint Surgery, Bijie Traditional Chinese Medicine Hospital, Bijie, 551700, China.
Huan XiaoDepartment of Bone and Joint Surgery, Bijie Traditional Chinese Medicine Hospital, Bijie, 551700, China.
Jian-Jun ZhouDepartment of Bone and Joint Surgery, Bijie Traditional Chinese Medicine Hospital, Bijie, 551700, China.
Fang LeiSecond Department of Orthopedics, Fifth Affiliated Hospital of Zunyi Medical University, Zhuhai, 519100, China.
Liang LiangSecond Department of Orthopedics, Fifth Affiliated Hospital of Zunyi Medical University, Zhuhai, 519100, China.
De-Wei WangSecond Department of Orthopedics, Fifth Affiliated Hospital of Zunyi Medical University, Zhuhai, 519100, China. wdw19761224@163.com.ORCID http://orcid.org/0000-0002-0616-3404

Funding

Bijie Science and Technology Bureau 'the open competition project' 2022Bijie Science and Technology Bureau 'the open competition project' no. BST Major Project No.1Health Commission of Guizhou Province gzwkj2024-400
6 · The paper itself

Abstract

objectiveThe aim of this study was to explore the influence of working length (determined by the screw position) on the stiffness and interfragmentary strain (IFS) of femoral locking compression plate (LCP) external fixators for lower tibial fractures under full weight-bearing conditions, with the goal of providing a reference basis for clinical applications.

methodsFinite element analysis software was used to construct a model of a lower tibial fracture with external femoral LCP fixation. The models were divided into four groups according to the different working lengths (external femoral locking plate fixation 1 [EF1], EF2, EF3, and EF4). Stress distribution clouds, fracture end displacements, stiffness and IFS were tested for each model group at different loads.

resultsCompared with those in the EF1 group, the stiffnesses in the EF2, EF3, and EF4 groups decreased by 28%, 31%, and 37%, respectively, under axial compression loading. Compared with those in the EF1 group, the stiffnesses in the EF2, EF3, and EF4 groups decreased by 19%, 33%, and 35%, respectively, under axial torsion loading. Compared with those in the EF1 group, the stiffnesses in the EF2, EF3, and EF4 groups decreased by 32%, 33%, and 35%, respectively, under a three-point bending load. The IFS of the four finite element models increased with the working length of the plate, with EF1 (76%) < EF2 (107%) < EF3 (110%) < EF4 (122%). Finite element analysis revealed that under full weight-bearing conditions, the structural stiffness of the femoral LCP external fixator decreased with increasing working length, leading to an increase in the IFS, which resulted in an IFS that exceeded the ideal range required for secondary healing.

conclusionFor unstable lower tibial fractures, screws in the femoral LCP external fixator should be placed as close to the fracture end as possible to increase stability and promote fracture healing.

Indexed as

Bone ScrewsTibial FracturesBiomechanical PhenomenaBone PlatesFinite Element AnalysisHumansStress, MechanicalWeight-BearingBiomechanicsDistal tibial fracturesExternal fixatorFinite element analysisFracture healingInterfragmentary strainLocking compression plateLower tibial fracturesScrew configurationScrew distributionWorking length

Identifiers

PMID40971087
PMCPMC12586413

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.