Evidence map›Paper›PMID 40970158›Full record

ArticleWearable technologies2025

Performance characterization of a novel semi-active exoskeleton for overhead work.

Jonas Schiebl, Christophe Maufroy, Nils Ziegenspeck, Christof Giers, Bassam Elmakhzangy, Urs Schneider, Thomas Bauernhansl

Abstract read
In one paragraph

Article in Wearable technologies, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Jonas SchieblFraunhofer Institute for Manufacturing Engineering and Automation IPA, Stuttgart, Germany.ORCID https://orcid.org/0000-0002-5276-004X
Christophe MaufroyFraunhofer Institute for Manufacturing Engineering and Automation IPA, Stuttgart, Germany.
Nils ZiegenspeckFraunhofer Institute for Manufacturing Engineering and Automation IPA, Stuttgart, Germany.
Christof GiersFraunhofer Institute for Manufacturing Engineering and Automation IPA, Stuttgart, Germany.
Bassam ElmakhzangyFraunhofer Institute for Manufacturing Engineering and Automation IPA, Stuttgart, Germany.
Urs SchneiderFraunhofer Institute for Manufacturing Engineering and Automation IPA, Stuttgart, Germany.
Thomas BauernhanslFraunhofer Institute for Manufacturing Engineering and Automation IPA, Stuttgart, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Occupational shoulder exoskeletons can relieve workers during strenuous overhead work. Passive solutions are lightweight, robust, and cost-effective, but they can also restrict user movement, have limited support, and cannot dynamically adapt to different working conditions. Semi-active and active systems are still mostly the subject of research, and existing systems are heavy or have limited performance and support. Here, we present a lightweight semi-active exoskeleton for shoulder support that incorporates a novel motorized torque adjustment mechanism that varies the effective lever arm with which a spring applies force to the supporting joint. The mechanism is integrated into lateral structures and can be actuated via Bowden cables with motors located on the user's back. The technical performance of the system was experimentally characterized in terms of its dynamic support torque profiles at six different support levels. Furthermore, adjustment times and energy consumption were investigated. The system showed plateau-like support torque profiles in the intended working range and could be adjusted from nearly 0 Nm up to 12 Nm of maximum support per arm. Adjustment times varied between 0.5 s for the adjustment of 20% of the total adjustment range and 1.0 s for a full activation/deactivation. Adjustments consumed between 0.1 As and 1.9 As of battery charge, allowing long operating times of up to one working day, using only a small 2 Ah battery. As a result, the exoskeleton provides high performance by combining comparatively high support, rapid motorized support adjustment, and low energy consumption in a lightweight design.

Indexed as

designexoskeletonsindustrymechatronicsperformance characterization

Identifiers

PMID40970158
PMCPMC12441634

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.