Evidence map›Paper›PMID 40969986›Full record

ArticleJournal of bioactive and compatible polymers2024

Fabrication and mechanical characterization of near field electrospun bioresorbable vascular grafts with fibrous architecture mimicking the arterial extracellular matrix.

Alexandra E Snyder, Jada K Sandridge, Adeline E Nordmoe, Evan N Main, Gary L Bowlin

Abstract read
In one paragraph

Article in Journal of bioactive and compatible polymers, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Alexandra E SnyderDepartment of Biomedical Engineering, The University of Memphis, Memphis, TN, USA.ORCID 0009-0000-5739-1637
Jada K SandridgeDepartment of Biomedical Engineering, The University of Memphis, Memphis, TN, USA.
Adeline E NordmoeDepartment of Biomedical Engineering, The University of Memphis, Memphis, TN, USA.
Evan N MainDepartment of Biomedical Engineering, The University of Memphis, Memphis, TN, USA.
Gary L BowlinDepartment of Biomedical Engineering, The University of Memphis, Memphis, TN, USA.

Funding

Downregulation of neutrophil extracellular traps by fibrous regeneration template design.R15EB033752 · NIBIB · UNIVERSITY OF MEMPHIS · PI BOWLIN, GARY L · 2023 to 2023
$415k
NIBIB NIH HHS R15 EB033752
6 · The paper itself

Abstract

Cardiovascular disease, arteriosclerosis, is characterized by the thickening of blood vessel (arteries) walls restricting blood flow and is a global health problem. One treatment option is a surgical procedure utilizing an autologous or synthetic vascular graft to bypass or replace the diseased arterial segment. The goal of this study was to fabricate and mechanically characterize near field electrospun bioresorbable vascular grafts with a fibrous architecture that mimics the arterial extracellular matrix. Polydioxanone vascular constructs with circumferential fiber alignment angles of 15°/75° and 30°/60° (0° representing circumferential fiber alignment) were fabricated using a custom built near-field electrospinning (NFES) system. The vascular construct mechanical properties were compared to the saphenous vein (SV) and internal mammary artery (IMA) through longitudinal and circumferential uniaxial mechanical testing, suture retention, and burst pressure evaluations. The results demonstrated that the 15°/75° templates were closest to mimicking the native vessel target properties as compared to the 30°/60°; however, neither of the vascular template designs achieved or exceeded all the target values. For the ultimate tensile strength, both the constructs met the SV value on the circumferential axis (2.61 MPa) and the IMA value on the longitudinal axis (4.3 MPa). In terms of suture retention, the 15°/75° template was the only construct that was in the IMA and SV targeted range of 138-200 gf. Finally, the burst pressure testing results indicated that neither of the vascular constructs achieved the level of the SV or IMA (1600-3196 mmHg), however, the 15° constructs were within the lower error of the SV. In conclusion, with further design modifications, NFES constructs have demonstrated promise as small-diameter vascular grafts by mimicking native arterial architecture and mechanical properties.

Indexed as

Near field electrospinningpolydioxanonevascular graftvascular tissue engineering

Identifiers

PMID40969986
PMCPMC12442793

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.