ArticleFrontiers in chemistry2025
Application of a fully 3D printed carbon electrode for the double potential step Chronoamperometric determination of 2,4-dinitrophenol in environmental water samples.
Article in Frontiers in chemistry, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Development of Binary Pd@PPyC-BiChemistry, an Asian journal · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Introduction: The detection of nitrophenolic compounds in environmental water sources is critical due to their toxicity and persistence. This study presents the first reported application of a fully 3D printed carbon nanofiber-graphite-polystyrene working electrode for the electrochemical determination of 2,4-dinitrophenol (2,4-DNP), offering a novel and potentially cost-effective alternative to traditionally fabricated electrodes. Methods: Initial characterisation of 2,4-DNP was performed using cyclic voltammetry across a pH range of 2-8 to investigate its redox behaviour. A double potential step chronoamperometric technique was then employed, with step potentials set at -1.4 V and +0.8 V. Calibration was conducted using standard solutions of 2,4-DNP, and the method was validated using both fortified and unfortified environmental pond water samples. Results: Cyclic voltammetry revealed two reduction peaks during the initial negative scan, attributed to the reduction of the nitro groups to hydroxylamines, followed by two oxidation peaks on the positive scan corresponding to the re-oxidation of these hydroxylamines. All peaks exhibited pH dependence. The chronoamperometric calibration curve was linear over the concentration range of 50 μM to 1.0 mM (R Discussion: The results demonstrate that 3D printed carbon nanofiber-graphite-polystyrene electrodes are effective for the determination of 2,4-DNP in environmental water samples. The method provides reliable quantification with good sensitivity and reproducibility, highlighting the potential of additive manufacturing in the development of electrochemical sensors for environmental monitoring.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.