Evidence map›Paper›PMID 40969392›Full record

ReviewMaterials today. Bio2025

Enhancing diagnostic reliability in non-invasive health Monitoring: An analytical framework for optimizing magnetic sensor-skin interactions in biomedical applications.

Wasim Ullah Khan, Mohammed Alissa, Huawei Ma, Uzair Aslam Bhatti, Abdullah Alghamdi, Mohammed A Alshehri, Abdullah Albelasi

Abstract readReview
In one paragraph

Review in Materials today. Bio, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Wasim Ullah KhanSchool of Information Engineering, Yango University, Fuzhou, 350015, Fujian, China.
Mohammed AlissaDepartment of Medical Laboratory, College of Applied Medical Sciences, Prince Sattam bin Abdulaziz University, Al-Kharj, 11942, Saudi Arabia.
Huawei MaSchool of Information Engineering, Hangzhou Medical College, No. 8, Yikang Street, Lin'an District, Hangzhou, 311399, China.
Uzair Aslam BhattiSchool of Information and Communication Engineering, Hainan University, China.
Abdullah AlghamdiDepartment of Medical Laboratory, College of Applied Medical Sciences, Prince Sattam bin Abdulaziz University, Al-Kharj, 11942, Saudi Arabia.
Mohammed A AlshehriDepartment of Medical Laboratory, College of Applied Medical Sciences, Prince Sattam bin Abdulaziz University, Al-Kharj, 11942, Saudi Arabia.
Abdullah AlbelasiDepartment of Medical Laboratories, College of Applied Medical Sciences, Shaqra University, Shaqra, 11961, Saudi Arabia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Magnetic sensors present a transformative solution for non-invasive biomedical monitoring by overcoming critical limitations associated with conventional sensing technologies, such as optical sensors, whose performance degrades due to sensor-skin coupling effects. We systematically examine the sensor-skin coupling effect, emphasizing its impact on diagnostic accuracy. Our analysis reveals the complex challenges associated with sensor-skin interfaces, including biomechanical, pigmentary, and textural variations that affect sensor performance. We introduce a novel methodology that combines advanced biomaterial development, adaptive calibration techniques, and sophisticated signal processing algorithms. Our findings highlight that skin-specific characteristics contribute to measurement uncertainties in existing sensing technologies, indicating an urgent need for adaptive interface solutions. We propose a conceptual model for developing biocompatible sensor interfaces that maintain measurement integrity across varied physiological conditions, drawing insights from materials science, bioengineering, and clinical research. This review provides a comprehensive examination of sensor-skin interactions and outlines a roadmap for next-generation health monitoring technologies, along with strategic recommendations for enhancing the reliability of non-invasive diagnostics through innovative biomaterial solutions.

Indexed as

And measurement uncertaintiesBiocompatible interfacesDiagnostic accuracyMagnetic sensorsNon-invasive monitoringOptical sensorsSensor-skin couplingWearable devices

Identifiers

PMID40969392
PMCPMC12441728

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.