Evidence map›Paper›PMID 40969064›Full record

ArticleSensors (Basel, Switzerland)2025

Evaluation of Optical and Thermal Properties of NIR-Blocking Ophthalmic Lenses Under Controlled Conditions.

Jae-Yeon Pyo, Min-Cheul Kim, Seung-Jin Oh, Ki-Choong Mah, Jae-Young Jang

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Jae-Yeon PyoDepartment of Optometry, Eulji University, 553 Sanseong-daero, Sujeong-gu, Seongnam-si 13135, Gyonggi-do, Republic of Korea.ORCID 0000-0002-8722-6015
Min-Cheul KimDepartment of Optometry, Sungwoon University, 105 Daehak-gil, Sinnyeong-myeon, Yeongcheon-si 38801, Gyeongsangbuk-do, Republic of Korea.ORCID 0000-0003-4139-5304
Seung-Jin OhDepartment of Optometry, Jeonbuk Science College, 117 Chungjeong-ro, Jeongeup-si 56204, Jeonbuk-do, Republic of Korea.ORCID 0009-0000-8887-9483
Ki-Choong MahDepartment of Optometry, Eulji University, 553 Sanseong-daero, Sujeong-gu, Seongnam-si 13135, Gyonggi-do, Republic of Korea.ORCID 0000-0001-7762-2615
Jae-Young JangDepartment of Optometry, Eulji University, 553 Sanseong-daero, Sujeong-gu, Seongnam-si 13135, Gyonggi-do, Republic of Korea.ORCID 0000-0002-3922-8542

Funding

Eulji University EJRG-24-13
6 · The paper itself

Abstract

This study evaluates the optical and thermal performance of near-infrared (NIR)-blocking spectacle lenses at luminous transmittance grades of 0, 2, and 3. Ten lens types were tested, including clear, tinted, and NIR-blocking spectacle lenses (NIBSL). The NIR blocking rate was measured across 780-1100 nm and 1100-1400 nm wavelength bands. Color reproduction was assessed using sharpness (MTF 50), point spread function (PSF), and color accuracy (ΔE

Indexed as

EyeglassesInfrared RaysAnimalsHumansSkin TemperatureSwineTemperaturecolor reproductionnear-infrared blocking ratenear-infrared-blocking spectacle lensesnear-infrared radiationoptical performancephotothermal effectsretinal safetythermal insulation

Identifiers

PMID40969064
PMCPMC12158342

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.