ArticleSensors (Basel, Switzerland)2025

Combining Infrared Thermography with Computer Vision Towards Automatic Detection and Localization of Air Leaks.

Ângela Semitela, João Silva, André F Girão, Samuel Verdasca, Rita Futre, Nuno Lau, José P Santos, António Completo

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Ângela SemitelaCentre of Mechanical Technology and Automation (TEMA), Department of Mechanical Engineering, University of Aveiro, 3810-193 Aveiro, Portugal.ORCID 0000-0002-4149-3804
João SilvaCentre of Mechanical Technology and Automation (TEMA), Department of Mechanical Engineering, University of Aveiro, 3810-193 Aveiro, Portugal.ORCID 0009-0002-9457-0532
André F GirãoCentre of Mechanical Technology and Automation (TEMA), Department of Mechanical Engineering, University of Aveiro, 3810-193 Aveiro, Portugal.ORCID 0000-0001-7282-885X
Samuel VerdascaCentre of Mechanical Technology and Automation (TEMA), Department of Mechanical Engineering, University of Aveiro, 3810-193 Aveiro, Portugal.ORCID 0009-0002-2081-6632
Rita FutreBosch Thermotechnology, S.A., Cacia, 3800-627 Aveiro, Portugal.ORCID 0000-0002-8983-9202
Nuno LauIntelligent Systems Associate Laboratory (LASI), 4800-058 Guimarães, Portugal.ORCID 0000-0003-0513-158X
José P SantosCentre of Mechanical Technology and Automation (TEMA), Department of Mechanical Engineering, University of Aveiro, 3810-193 Aveiro, Portugal.ORCID 0000-0003-0417-8167
António CompletoCentre of Mechanical Technology and Automation (TEMA), Department of Mechanical Engineering, University of Aveiro, 3810-193 Aveiro, Portugal.ORCID 0000-0002-3972-8432

Funding

Programa Operacional Competitividade e Internacionalização UID 00481PRR - Plano de Recuperação e Resiliência under the Next Generation EU from the European Union C644919832-00000035 | Project nº 46
6 · The paper itself

Abstract

This paper proposes an automated system integrating infrared thermography (IRT) and computer vision for air leak detection and localization in end-of-line (EOL) testing stations. This system consists of (1) a leak tester for detection and quantification of leaks, (2) an infrared camera for real-time thermal image acquisition; and (3) an algorithm for automatic leak localization. The python-based algorithm acquires thermal frames from the camera's streaming video, identifies potential leak regions by selecting a region of interest, mitigates environmental interferences via image processing, and pinpoints leaks by employing pixel intensity thresholding. A closed circuit with an embedded leak system simulated relevant leakage scenarios, varying leak apertures (ranging from 0.25 to 3 mm), and camera-leak system distances (0.2 and 1 m). Results confirmed that (1) the leak tester effectively detected and quantified leaks, with larger apertures generating higher leak rates; (2) the IRT performance was highly dependent on leak aperture and camera-leak system distance, confirming that shorter distances improve localization accuracy; and (3) the algorithm localized all leaks in both lab and industrial environments, regardless of the camera-leak system distance, mostly achieving accuracies higher than 0.7. Overall, the combined system demonstrated great potential for long-term implementation in EOL leakage stations in the manufacturing sector, offering an effective and cost-effective alternative for manual inspections.

Indexed as

air leaksalgorithmcomputer visiondistanceinfrared thermographyleak aperturelocalization