Comparative analysis of eMC algorithm dose calculations using GATE validation: impact of tissue heterogeneity on electron beam dosimetry.

Mohammed Rezzoug, Mustapha Zerfaoui, Yassine Oulhouq, Abdeslem Rrhioua, Omar Hamzaoui, Dikra Bakari

Abstract readComparative StudyValidation Study
PubMed Publisher
In one paragraph

Article in Physical and engineering sciences in medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Mohammed RezzougLaboratory of Theoretical Physics, Particles, Modeling and Energy (LPTPME), Faculty of Sciences, University Mohamed 1st, Boulevard Mohamed VI, BP 717, 60000, Oujda, Morocco. med.rezzoug@ump.ac.ma.ORCID http://orcid.org/0000-0001-6184-7203
Mustapha ZerfaouiLaboratory of Theoretical Physics, Particles, Modeling and Energy (LPTPME), Faculty of Sciences, University Mohamed 1st, Boulevard Mohamed VI, BP 717, 60000, Oujda, Morocco.
Yassine OulhouqLaboratory of Theoretical Physics, Particles, Modeling and Energy (LPTPME), Faculty of Sciences, University Mohamed 1st, Boulevard Mohamed VI, BP 717, 60000, Oujda, Morocco.
Abdeslem RrhiouaLaboratory of Theoretical Physics, Particles, Modeling and Energy (LPTPME), Faculty of Sciences, University Mohamed 1st, Boulevard Mohamed VI, BP 717, 60000, Oujda, Morocco.
Omar HamzaouiLaboratory of Theoretical Physics, Particles, Modeling and Energy (LPTPME), Faculty of Sciences, University Mohamed 1st, Boulevard Mohamed VI, BP 717, 60000, Oujda, Morocco.
Dikra BakariEGIS Laboratory, National School of Applied Sciences, University Mohamed 1st, Oujda, Morocco.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeElectron beam radiotherapy is a crucial modality for treating superficial tumors. Accurate dose calculation is essential for treatment efficacy and minimizing side effects. While Monte Carlo (MC) simulations are considered the gold standard for dose calculation, their computational cost can be prohibitive. The electron Monte Carlo (eMC) algorithm offers a faster alternative, but its accuracy, especially in heterogeneous environments, remains a concern. METHODS AND MATERIALS: This study compares electron beam dose distributions calculated using the eMC algorithm in a treatment planning system (TPS) with those obtained from full MC simulations using the GATE platform. We evaluated the eMC algorithm's performance across various electron energies (6, 9, and 12 MeV) and field sizes (6 × 6 cm

resultsResults in homogeneous phantoms demonstrated generally good agreement between eMC and GATE, with some discrepancies observed in penumbra regions and at higher energies, particularly for larger field sizes. In heterogeneous phantoms, significant deviations were observed, particularly in lateral dose profiles near density interfaces and at higher beam energies, with percentage of points with less than 3% difference dropping considerably.

conclusionThese findings highlight the limitations of the eMC algorithm in accurately modeling complex tissue heterogeneities. While eMC provides acceptable accuracy in relatively simple scenarios, its performance degrades significantly in clinically realistic heterogeneous environments, necessitating caution in treatment planning and highlighting the ongoing need for improved dose calculation algorithms.

Indexed as

AlgorithmsElectronsMonte Carlo MethodRadiometryHumansPhantoms, ImagingRadiotherapy DosageRadiotherapy Planning, Computer-AssistedDose distributionElectron beam radiotherapyElectron Monte Carlo (eMC) algorithmHeterogeneous phantomMonte Carlo simulation