Evidence map›Paper›PMID 40965119›Full record

ArticleJournal of medical radiation sciences2026

Patient Dose Optimisation of Abdominopelvic Protocols During X-Ray Imaging.

Emmanuel Ekem-Ferguson, Shirazu Issahaku, Mark Pokoo-Aikins, Mary Boadu

Abstract read
In one paragraph

Article in Journal of medical radiation sciences, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Emmanuel Ekem-FergusonDepartment of Medical Physics, University of Ghana, Legon, Accra, Ghana.ORCID https://orcid.org/0009-0004-1134-1908
Shirazu IssahakuDepartment of Medical Physics, University of Ghana, Legon, Accra, Ghana.
Mark Pokoo-AikinsDepartment of Medical Physics, University of Ghana, Legon, Accra, Ghana.ORCID https://orcid.org/0000-0003-0366-6708
Mary BoaduDepartment of Medical Physics, University of Ghana, Legon, Accra, Ghana.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionAbdominopelvic radiography is commonly performed in both supine and erect positions, raising concerns about radiation dose exposure. In Ghana, there is limited data on organ dose evaluation in these examinations, particularly regarding patient positioning for dose optimisation. Additionally, the risk of dose creep in Digital Radiography (DR) due to its wide dynamic range further complicates dose management. This study aimed to estimate organ doses for patients undergoing abdominopelvic radiography in both positions and to develop an optimisation strategy that minimises radiation exposure while maintaining image quality.

methodsOrgan doses were estimated using CalDose X 5.0 for 112 patients across two facilities in both erect and supine positions. Image quality was assessed using signal-to-noise ratio (SNR) values for five specific organs, with the kidney, the liver, and the prostate selected for dose and image quality optimisation. Additionally, 34 exposures were performed on an anthropomorphic phantom using varying exposure parameters and focus-to-detector distances (FDD), with thermoluminescence dosimeters (TLDs) employed for dose optimisation measurement.

resultsAn average of 39.9% and 52.9% of radiographs had optimal and high SNR values respectively. After the optimisation procedure, the recommended exposure parameters were 70 kVp, 10 mAs, and 110 cm FDD for both positions. In the supine position, organ doses reduced with a percentage difference of 50.0, 65.22 and 19.21, and 23.03, 28.97 and 30.98 for SNR for the kidney, the liver and the prostate respectively. In the erect position, organ doses reduced with a percentage difference of 72.34, 72 and 4.55, and SNR percentage difference of 10.69, 9.39 and 32.83 for the kidney, the liver and the prostate respectively.

conclusionAbdominopelvic organ doses vary based on patient demographics and exposure settings. The optimisation strategy significantly reduced radiation doses while preserving image quality. These findings emphasise the importance of standardised imaging protocols to enhance patient safety and radiation protection in clinical practice.

Indexed as

AbdomenPelvisRadiation DosageRadiography, AbdominalAdultAgedFemaleHumansMaleMiddle AgedPatient PositioningPhantoms, ImagingSignal-To-Noise RatioYoung Adultabdomendigital radiographydosemedical imaging

Identifiers

PMID40965119
PMCPMC13238575

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.