Evidence map›Paper›PMID 40962804›Full record

ArticleScientific reports2025

Comprehensive structural model for the evaluation of HME humidification properties.

Ingolf Meineke, Klaus Züchner

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Ingolf MeinekeDepartment Clinical Pharmacology, University Medical Centre, Robert-Koch-Str. 40, D-37075, Göttingen, Germany. imeineke@med.uni-goettingen.de.
Klaus ZüchnerDepartment Anaesthesiology, University Medical Centre, Robert-Koch-Str. 40, D-37075, Göttingen, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

HMEs (heat and moisture exchangers) are employed in clinical practice to humidify the inspired air in intubated patients. We aimed to develop and experimentally validate a mass based model describing the water input-output equilibrium in the presence of HMEs. The model should serve as a universally applicable basis for the evaluation of the fundamental HME humidification properties performance (mg reversibly stored per breath) and efficiency. A plug flow model was designed using three different locations (gas inlet, moisture benefit and water output) for inspiratory-expiratory flow and humidity measurements. We developed a complete set of algorithms for the calculation of all relevant metrics. Measurements also assessed humidity dependent volume changes. We proved the concept through the validation of humidity predictions without HME in the test setup at target humidities of 37 and 44 mg/l respectively with the inspiratory volume of 0.25, 0.50 and 0.75 l. The concept was applied in the evaluation of a random sample of HMEs. Differences between prediction and measurements ranged between − 1.89 and 2.24 mg/l. For moisture benefit a mean difference of 0.15 mg/l (sd 0.69) was found and for water output of -0.48 mg/l (sd 0.98). Humidification caused a significant volume increase up to 6.6% with respect to the inspired dry air. HME performance results of five HME brands ranged from 5 to 30 mg overall. Performance results derived from moisture benefit and water output agreed within 5% of the common mean. Efficiency results can be above 80% over the whole measurement range or below 20% at high water load depending on the HME brand. Thus, HMEs can be sorted by registering efficiency at the upper bound of the tidal volume range. HMEs for laryngectomized patients (LE-HMEs) showed much lower performances between 2 and 5 mg per breath due to their small size. A novel comprehensive research environment, both theoretical and experimental, enables the assessment of HME properties and gives qualitative and quantitative definitions of HME performance and efficiency for clinical use.

Indexed as

EfficiencyHeat and moisture exchangerHMELE-HMEMethod validationModel calculator programPerformance

Identifiers

PMID40962804
PMCPMC12443951

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.