Evidence map›Paper›PMID 40961042›Full record

ArticlePloS one2025

Evaluation of the cobas plasma separation card to identify HIV-infected patients in virological failure in real-life conditions in Vietnam.

Hanh Thi Hong Ngo, Binh Thanh Nguyen, Tram Thi Phuong Pham, Nhung Thi Hong Le, Hien Ba Pham, Trang Thi Thu Nguyen, Mohand Ait-Ahmed, Tuan Anh Nguyen, Thang Hong Pham, Yoann Madec

Abstract read
In one paragraph

Article in PloS one, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Hanh Thi Hong NgoNational Reference Laboratory of HIV Molecular Biology, National Institute of Hygiene and Epidemiology, Hanoi, Vietnam.ORCID 0000-0001-5188-4043
Binh Thanh NguyenNational Reference Laboratory of HIV Molecular Biology, National Institute of Hygiene and Epidemiology, Hanoi, Vietnam.
Tram Thi Phuong PhamNational Reference Laboratory of HIV Molecular Biology, National Institute of Hygiene and Epidemiology, Hanoi, Vietnam.
Nhung Thi Hong LeNational Reference Laboratory of HIV Molecular Biology, National Institute of Hygiene and Epidemiology, Hanoi, Vietnam.
Hien Ba PhamDong Da General Hospital, Hanoi, Vietnam.
Trang Thi Thu NguyenNam Tu Liem District Medical Center, Hanoi, Vietnam.
Mohand Ait-AhmedCenter for Translational Research, Institut Pasteur, Université de Paris, Paris, France.
Tuan Anh NguyenNational Reference Laboratory of HIV Molecular Biology, National Institute of Hygiene and Epidemiology, Hanoi, Vietnam.
Thang Hong PhamNational Reference Laboratory of HIV Molecular Biology, National Institute of Hygiene and Epidemiology, Hanoi, Vietnam.
Yoann MadecEpidemiology of Emerging Diseases Unit, Institut Pasteur, Université de Paris, Paris, France.ORCID 0000-0002-6201-1261

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe standard of care for HIV-infected patients on antiretroviral therapy (ART) relies on regular monitoring of HIV viral load. Access to viral load monitoring has improved in recent years, but remains scarce in some settings. Alternatives to plasma, such as dried specimens, can help bring routine viral load testing to remote settings. This study aimed to evaluate performances of the cobas® plasma separation card (PSC) to detect virological failure at the threshold of 1,000 copies/mL in real-life conditions in Vietnam.

settingPatients were enrolled in two hospitals in Hanoi (Vietnam).

methodsThis cross-sectional evaluation enrolled 250 HIV-infected adults using convenience sampling. All provided plasma and PSC samples. The sensitivity and specificity of PSC, as compared to plasma, to identify patients in virological failure were estimated. Convenience sampling was used to reach the target numbers of 150 and 100 patients with plasma viral load ≥ and <1,000 copies/mL, respectively.

resultsOverall, 250 patients were enrolled. Of the 127 (50.8%) patients with plasma viral load ≥1,000 copies/mL, the PSC viral load was also ≥1,000 copies/mL in 126 (sensitivity (95% confidence interval (CI)): 99.2% (95.7-99.9)). Of the 123 (49.2%) patients with plasma viral load <1,000 copies/mL, the PSC viral load was also <1,000 copies/mL in 108 (specificity (95% CI): 87.8% (80.7-93.0)). Overall, the concordance rate was 93.6%.

conclusionsThis field evaluation of the cobas® PSC showed its high effectiveness in identifying patients in virological failure. The specificity was 87.8%, lower than in previous reports. However, in cases of discrepancy, the PSC viral load level was never far from the 1,000 copies/mL threshold, which may be due to measurement error inherent to the technique.

Indexed as

HIV InfectionsViral LoadAdultCross-Sectional StudiesFemaleHIV-1HumansMaleMiddle AgedRNA, ViralSensitivity and SpecificityVietnamRNA, Viral

Identifiers

PMID40961042
PMCPMC12443287

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.