Evidence map›Paper›PMID 40960595›Full record

ArticleAesthetic plastic surgery2026

Assessing the Thermal Effects of Noble Gas Plasma Therapy: A Preclinical Investigation.

Xinrui Zhang, Trinh Thi Thuy Tien, Yongxun Jin, Shuyi Zhou, Nguyen Ngan Giang, Linh Thi Thuy Le, Young-Hyun Lee, Gun Young Ahn, Boncheol Leo Goo, Kyoung Su Jung and 3 more

Abstract read
PubMed Publisher
In one paragraph

Article in Aesthetic plastic surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors.

Xinrui ZhangDepartment of Plastic and Reconstructive Surgery, College of Medicine, Seoul National University, Seoul, 03080, Republic of Korea.
Trinh Thi Thuy TienDepartment of Plastic and Reconstructive Surgery, Seoul National University Bundang Hospital, Seongnam, 13620, Republic of Korea.
Yongxun JinDepartment of Plastic and Reconstructive Surgery, College of Medicine, Seoul National University, Seoul, 03080, Republic of Korea.
Shuyi ZhouDepartment of Plastic and Reconstructive Surgery, College of Medicine, Seoul National University, Seoul, 03080, Republic of Korea.
Nguyen Ngan GiangDepartment of Plastic and Reconstructive Surgery, Seoul National University Bundang Hospital, Seongnam, 13620, Republic of Korea.
Linh Thi Thuy LeDepartment of Plastic and Reconstructive Surgery, Seoul National University Bundang Hospital, Seongnam, 13620, Republic of Korea.
Young-Hyun LeeKorean Institute of Nonclinical Study, Seongnam, 13605, Republic of Korea.
Gun Young AhnGowoonsesang Dermatology Clinic, Seoul, 06055, Republic of Korea.
Boncheol Leo GooNaeum Dermatology and Aesthetics Clinic, Seoul, 04512, Republic of Korea.
Kyoung Su JungAgnes Medical Co., Ltd., Seongnam, 13591, Republic of Korea.
Hyun Soo HwangAgnes Medical Co., Ltd., Seongnam, 13591, Republic of Korea.
Pham Ngoc ChienDepartment of Plastic and Reconstructive Surgery, Seoul National University Bundang Hospital, Seongnam, 13620, Republic of Korea. ngocchien1781@gmail.com.ORCID 0000-0003-1419-3766
Chan Yeong HeoDepartment of Plastic and Reconstructive Surgery, College of Medicine, Seoul National University, Seoul, 03080, Republic of Korea. lionheo@snu.ac.kr.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Gas plasma treatment is an emerging technology in skincare that uses ionized gas to treat various skin conditions. This treatment involves generating plasma, a state of matter where gas is energized to a point where it becomes highly reactive, with the ability to kill bacteria, promote healing, and stimulate skin regeneration. The test device "PlazMagik" is a noble gas plasma device that utilizes helium or argon gas to generate cold-temperature plasma energy. It offers the flexibility to utilize either helium, argon, or a combination of both gases. We evaluate the thermal image area, the maximum temperature, the time to reach basal temperature, and tissue necrosis using, skin, liver, and femoral muscle tissue collected from mini pigs. The results indicate that higher output energy levels of a device expand the area of tissue impact under standardized test conditions. The continuous-wave (CW) mode generates significantly more thermal effect than the pulse mode at the same energy levels. The triple-tip device causes thermal effects two to three times greater than the single-tip device. Peak tissue temperatures depend on energy levels, reaching 32 °C, 50 °C, and 70 °C at increasing levels, with higher temperatures causing quicker tissue damage. Recovery time to baseline temperature increases with higher temperatures. Higher energy levels increase the likelihood of tissue necrosis, especially in hepatic tissue. CW mode is more likely to cause tissue necrosis than pulse mode. Variations in the settings (output level, mode, or tips) are the cause of changes seen in the thermal imaging area, maximum temperature, time to reach basal temperature, and findings of the histopathological examination. Gas plasma devices can be used safely and moderately without endangering the body. Thermal effects of plasma therapy: The study evaluates the thermal effects of a noble gas plasma device (PlazMagik) on skin, liver, and muscle tissues from mini pigs, focusing on parameters like thermal imaging area, peak temperature, and tissue necrosis. Impact of device settings: Higher energy output levels, continuous-wave (CW) mode, and triple-tip devices lead to greater thermal effects, higher peak temperatures (up to 70°C), and increased likelihood of tissue necrosis compared to pulse mode and single-tip devices. Tissue-specific response: Liver tissue is more susceptible to plasma-induced necrosis than skin or muscle. Recovery time to baseline temperature increases with higher energy levels. Safety and clinical implications: Controlled and moderate use of noble gas plasma therapy is safe, but standardization of treatment protocols is necessary for clinical applications. The therapy shows promise for noninvasive skin treatments, wound healing, and dermatological applications. Level of Evidence III This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

Indexed as

ArgonHeliumPlasma GasesAnimalsNecrosisSwineSwine, MiniatureArgonHeliumPlasma GasesGas plasma deviceNecrosisSafety assessmentThermal tissue effectTreatment

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.