Evidence map›Paper›PMID 40958998›Full record

ArticleJSES international2025

Assessing the accuracy of a machine learning prediction for 2 different shoulder prostheses: an external validation study.

Gianluca Caprili, Andrea G Calamita, Michele Novi, Domenico A Campanacci, Simone Nicoletti

Abstract read
In one paragraph

Article in JSES international, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Gianluca CapriliProsthetic Orthopedics, San Pietro Igneo Hospital, Fucecchio, FI, Italy.
Andrea G CalamitaProsthetic Orthopedics, San Pietro Igneo Hospital, Fucecchio, FI, Italy.
Michele NoviProsthetic Orthopedics, San Pietro Igneo Hospital, Fucecchio, FI, Italy.
Domenico A CampanacciDepartment of Orthopaedic Oncology, Careggi University Hospital, Firenze, Italy.
Simone NicolettiProsthetic Orthopedics, San Pietro Igneo Hospital, Fucecchio, FI, Italy.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The integration of machine learning in orthopedic surgery, including shoulder procedures, has garnered increasing interest. This retrospective analysis aims to externally validate a predictive analytics platform within a patient cohort undergoing reverse total shoulder arthroplasty for eccentric or concentric glenohumeral osteoarthritis. Methods: Ninety patients who underwent reverse total shoulder arthroplasty at our institution in 2022 were selected for this study. Patients were divided into 2 groups based on the type of implant (50 Exactech Equinoxe and 40 Zimmer Biomet Comprehensive). Preoperative evaluations included 19 variables per the tool requirements (demographics, diagnosis, comorbidities, patient-reported pain and function, and range of motion). The study compared the tool's outcome predictions with postoperative outcomes at 3-6 months, 1 year, and 2 years postsurgery for visual analog scale and active range of movement. We also quantified the mean absolute error (MAE) separately in the 2 groups and compared it to the MAE from the internal validation of the same tool. Results: Significant improvements in visual analog scale, active forward elevation, active abduction, and active external rotation met the minimal clinically important difference at 3-6 months, 1 year, and 2 years in both implant groups. Additionally, a modest improvement in active internal rotation was observed in both cohorts. In terms of MAE, we found a higher error than the internal validation only for forward elevation at 3-6 months in group 2 and a lower error in all the other outcome measures at all time points for both groups. Conclusion: The predictive analytics platform demonstrated a lower or similar MAE than the internal validation for both groups. Notably, we found that the tool's predictions are generalizable to another shoulder prosthesis, even though it was not trained on that particular product. This tool holds promise for aiding clinicians in managing patient expectations.

Indexed as

Artificial intelligenceExternal validationGlenohumeral osteoarthritisMachine learningOutcome predictionReverse shoulder

Identifiers

PMID40958998
PMCPMC12435022

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.