Evidence map›Paper›PMID 40958131›Full record

ArticleKnee surgery & related research2025

Effect of the kinematic retaining design on knee kinematics in total knee arthroplasty: A cadaveric study using a navigation system.

Tomofumi Kinoshita, Kazunori Hino, Tatsuhiko Kutsuna, Kunihiko Watamori, Takashi Tsuda, Yusuke Horita, Masaki Takao

Abstract read
In one paragraph

Article in Knee surgery & related research, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Tomofumi KinoshitaDepartment of Orthopaedic Surgery, Ehime University Graduate School of Medicine, Toon, Ehime, Japan.
Kazunori HinoDepartment of Joint Reconstruction, Ehime University Graduate School of Medicine, Toon, Ehime, Japan. ehukne@gmail.com.
Tatsuhiko KutsunaDepartment of Orthopaedic Surgery, Ehime University Graduate School of Medicine, Toon, Ehime, Japan.
Kunihiko WatamoriDepartment of Joint Reconstruction, Ehime University Graduate School of Medicine, Toon, Ehime, Japan.
Takashi TsudaDepartment of Orthopaedic Surgery, Ehime University Graduate School of Medicine, Toon, Ehime, Japan.
Yusuke HoritaDepartment of Orthopaedic Surgery, Ehime University Graduate School of Medicine, Toon, Ehime, Japan.
Masaki TakaoDepartment of Orthopaedic Surgery, Ehime University Graduate School of Medicine, Toon, Ehime, Japan.

Funding

Japan Orthopaedics and Traumatology Foundation 531JSPS KAKENHI 24K19622
6 · The paper itself

Abstract

backgroundImplant design in total knee arthroplasty (TKA) has evolved considerably, with recent developments focusing on reproducing native knee kinematics. Some implants now feature anatomically and physiologically accurate articular surface geometries. This study aimed to evaluate the impact of different implant designs on knee kinematics using the same cadaveric specimens to ensure consistent comparison. We hypothesized that implant designs incorporating features intended to replicate native joint anatomy, such as the kinematic retaining (KR) design, would more closely reproduce physiological knee kinematics.

methodsTKA was performed on nine Thiel-embalmed cadaveric knees with mild medial osteoarthritis, using three implant designs from the Physica system: KR, cruciate retaining (CR), and medial congruent (MC) designs. All procedures were performed using a mechanical alignment technique, with both the posterior tibial slope and femoral rotational angle standardized at 3°. The posterior cruciate ligament was preserved throughout the evaluation of all implant designs. A navigation system was used to collect detailed kinematic data. Evaluations were conducted after trial component placement, focusing on anteroposterior, mediolateral, and compression-distraction positions, as well as rotational angles. From these knee status data, femoral rotational kinematics relative to the tibia and the anteroposterior translation of both femoral condyles during flexion were also calculated.

resultsNo significant differences in flexion and extension angles were observed between the groups. The KR group presented the greatest mean femoral external rotation relative to the tibia throughout the range of motion among the groups; however, there were no statistically significant differences. The CR and MC group showed significantly reduced anteroposterior translation of the lateral condyle compared with the native knee (p = 0.021 and 0.003, respectively). Furthermore, the anteroposterior translation of the lateral femoral condyle was significantly greater in the KR group than in MC groups (p = 0.021). In the KR group, six of nine knees exhibited medial pivot motion, compared with three in the CR group and four in the MC group.

conclusionsUsing identical cadaveric specimens and navigation-based analysis, we identified distinct kinematic profiles associated with each implant design. Notably, the KR implant demonstrated kinematics approximating native knee motion; however, these findings remain preliminary and warrant further clinical validation. LEVEL OF EVIDENCE: III.

Indexed as

Cadaver studyKinematic retainingKnee kinematicsMedial pivotTotal knee arthroplasty

Identifiers

PMID40958131
PMCPMC12442271

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.