ArticleMicrosystems & nanoengineering2025
Electroosmotic hydraulic-based haptic reproduction of human pulse with high accuracy for remote diagnosis.
Article in Microsystems & nanoengineering, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Shared expectations of soft haptic feedback through imagined high-fives with robots and non-human animals at a science festival.Scientific reports · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
Haptic pulse reproduction technology enables physicians to conduct remote, contact-free pulse diagnosis by transcending temporal and spatial constraints in traditional medical practice. However, current systems face challenges in accurately reproducing realistic pulse haptic feedback, which impacts diagnostic reliability. Here, we developed an electroosmotic hydraulic-based pulse haptic reproduction interface (PHRI) system that can precisely reproduce realistic haptic information of the human pulse. This PHRI system demonstrates the rapid response and precise control of electroosmotic hydraulics, achieving a frequency response of 500 Hz and an output force of 100 mN at 160 V driving voltage. Besides, time-domain and frequency-domain analyses further confirm high accuracy, with a correlation coefficient of 0.99 between reproduced and actual pulses. When tested under varying pressures, the PHRI system shows a small root mean square error of <1 Pa in frequency spectra. This PHRI technology provides a robust platform for remote pulse diagnosis and advances the integration of traditional Chinese medicine with telemedicine systems.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.