Evidence map›Paper›PMID 40954499›Full record

ArticleBiomedical engineering online2025

Automatic position monitoring of endotracheal breathing tubes using a magnetic sensor array.

Till Riemschneider, Thorben Schüthe, Robert Werdehausen, Thomas Schilling, Thomas Hachenberg

Abstract read
In one paragraph

Article in Biomedical engineering online, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Till RiemschneiderDepartment of Anesthesiology and Intensive Care Medicine, Medical Faculty, Otto von Guericke University of Magdeburg, Leipziger Str. 44, 39120, Magdeburg, Germany. till.riemschneider@med.ovgu.de.
Thorben SchütheFaculty of Engineering and Computer Sciences, University of Applied Sciences Hamburg, Berliner Tor 7, 20099, Hamburg, Germany.
Robert WerdehausenDepartment of Anesthesiology and Intensive Care Medicine, Medical Faculty, Otto von Guericke University of Magdeburg, Leipziger Str. 44, 39120, Magdeburg, Germany.
Thomas SchillingCenter of Anesthesiology and Intensive Care Medicine, Klinikum Magdeburg, Birkenallee 34, 39130, Magdeburg, Germany.
Thomas HachenbergDepartment of Anesthesiology and Intensive Care Medicine, Medical Faculty, Otto von Guericke University of Magdeburg, Leipziger Str. 44, 39120, Magdeburg, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundDislocation of an endotracheal tube (ETT) during invasive ventilation can lead to serious events such as unilateral ventilation or unintentional extubation. The correct position of the endotracheal tube is determined visually. X-ray imaging or invasive procedures such as bronchoscopy are established for repeated position verification. However, these measures are time-consuming and only provide a limited number of snapshots. A new monitoring method can recognize dislocations of the ETT. The proposed system operates automatically without the need for continuous staff awareness or interaction. MATERIALS AND

methodsA ring-shaped permanent magnet is attached to the ETT. A small device is placed extracorporeally on the patient to detect the magnetic field. This device uses 64 magnetic sensors arranged as a sensor array in an 8x8 matrix. The sensor signals are digitally converted, enabling the position of the ETT with the attached magnet to be determined by software. Two processing methods (image similarity and localization) are tested for monitoring. The prototype system detects displacements with millimeter scale positioning deviations in our tests.

resultsOur system triggers an alarm upon detecting an impermissible dislocation, complete extubation, or unintended bronchial intubation. The proposed methods were validated on a sensor array prototype and assessed through a dedicated experimental setup. The results are promising and could lead to further development towards clinical usability.

conclusionEarly warnings would be particularly advantageous, even for minor or beginning dislocations of the ETT. An automated continuous tube monitoring process could help reduce the workload of the staff and improve patient safety.

Indexed as

Intubation, IntratrachealMagnetic PhenomenaRespirationAutomationHumansMonitoring, PhysiologicEndotracheal TubusIntensive Care MonitoringLong-Term VentilationMagnetic LocalizationMagnetic Sensor ArrayMagnetic TrackingTubus DislocationUndesired Extubation

Identifiers

PMID40954499
PMCPMC12439367

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.