Evidence map›Paper›PMID 40954379›Full record

ArticleRadiological physics and technology2025

Improved denoising scheme using three-dimensional multi-zone convolutional neural filters in dedicated breast positron emission tomography images.

Masahiro Tsukijima, Atsushi Teramoto, Akihiro Kojima, Osamu Yamamuro, Kumiko Oomi, Hiroshi Fujita

Abstract read
PubMed Publisher
In one paragraph

Article in Radiological physics and technology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Masahiro TsukijimaEast Nagoya Image Diagnosis Center, Nagoya, Japan. tsukijimamasahiro@gmail.com.ORCID http://orcid.org/0009-0005-1620-9364
Atsushi TeramotoFaculty of Engineering, Meijo University, Nagoya, Japan.
Akihiro KojimaNagoya PET Imaging Center, Nagoya, Japan.
Osamu YamamuroEast Nagoya Image Diagnosis Center, Nagoya, Japan.
Kumiko OomiEast Nagoya Image Diagnosis Center, Nagoya, Japan.
Hiroshi FujitaFaculty of Engineering, Gifu University, Gifu, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Dedicated breast positron emission tomography (dbPET) has higher spatial resolution than whole-body PET and can detect smaller lesions. Therefore, it is expected to be useful in detecting early stage breast cancer and assessing treatment efficacy. However, dbPET images suffer leading to a relative increase in noise from reduced sensitivity. In a previous study, optimized noise reduction for each region was achieved by applying multiple convolutional neural networks (CNNs). However, CNN processing was performed in a two-dimensional (2D) slice plane, which resulted in image blurring when the image was observed from multiple directions using maximum intensity projection (MIP). In this study, we aimed to further reduce noise and improve visibility by extending multiple CNNs to the three-dimensional (3D) processing and optimizing them for each region. To train the CNN, data with acquisition times of 1 and 7 min were used as the input and teacher images, respectively. Furthermore, 3D volume data were used as the input, and the system was designed to output volume data after noise reduction processing. Quantitative evaluation of the proposed multiple 3D direction-denoising filter showed better performance than that of the 2D filter. Furthermore, the visibility of the MIP images improved. In addition, the quantitative evaluation of the maximum standardized uptake value (SUV

Indexed as

BreastBreast NeoplasmsImaging, Three-DimensionalNeural Networks, ComputerPositron-Emission TomographySignal-To-Noise RatioFemaleHumansBreast cancer imagingConvolutional neural networksDedicated breast PETQuantitative valueThree-dimensional denoising filter

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.