ArticleMagnetic resonance in medicine2026
Extending real-time MRI of the oral cavity using simultaneous multislice and compressed sensing.
Article in Magnetic resonance in medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Extending real-time MRI of the oral cavity using simultaneous multislice and compressed sensing.Magnetic resonance in medicine · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
purposeTo demonstrate a real-time MRI (rtMRI) sequence that can image multiple slices simultaneously and apply them to image the dynamics of the oral cavity. Specifically, we demonstrate the imaging of tongue movement, speech, and swallowing.
methodsWe developed a radial rtMRI sequence with multiband excitation. Two sampling schemes were explored: a golden-angle trajectory and a golden-angle trajectory adapted for simultaneous multislice acceleration. Additionally, we developed a compressed sensing reconstruction pipeline. Phantom and in vivo rtMRI data were acquired on a 3 T system using a standard head/neck coil.
resultsWe show that the proposed technique can acquire rtMRI videos at a range of temporal resolutions (up to 25 ms). Example applications of tongue movement, speech, and swallowing are shown. Additionally, we show that the sequence is robust to changes in slice distance and coil compression level.
conclusionCombining rtMRI with multiband excitation and compressed sensing reconstruction enables imaging of the oral cavity at high (up to 25 ms) temporal resolution.