Evidence map›Paper›PMID 40952408›Full record

ArticleWater science and technology : a journal of the International Association on Water Pollution Research2025

Enhancing drainage pipeline inspection: advanced integration of six-axis sensor fusion and extended Kalman filter.

Jinheng Meng, Yunlong Xiao, Hexiang Yan, Jiaying Wang, Kunlun Xin, Tao Tao

Abstract read
PubMed Publisher
In one paragraph

Article in Water science and technology : a journal of the International Association on Water Pollution Research, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Jinheng MengCollege of Environmental Science and Engineering, Tongji University, Shanghai 200092, China.ORCID https://orcid.org/0009-0003-6254-4150
Yunlong XiaoCollege of Environmental Science and Engineering, Tongji University, Shanghai 200092, China.
Hexiang YanCollege of Environmental Science and Engineering, Tongji University, Shanghai 200092, China.
Jiaying WangCollege of Environmental Science and Engineering, Tongji University, Shanghai 200092, China E-mail: 18614@tongji.edu.cn.
Kunlun XinCollege of Environmental Science and Engineering, Tongji University, Shanghai 200092, China.
Tao TaoCollege of Environmental Science and Engineering, Tongji University, Shanghai 200092, China E-mail: taotao@tongji.edu.cn.ORCID https://orcid.org/0000-0003-4214-7097

Funding

National Natural Science Foundation of China 52470109
6 · The paper itself

Abstract

Urban water environment pollution is a pressing global concern, particularly in developing countries where inadequate infrastructure contributes significantly to this challenge. This study builds upon these principles by enhancing drainage pipeline inspection technologies, aiming to streamline processes and reduce resource consumption. This research advances the integration of gyroscopes and accelerometers within a sextuple-axis sensor framework, streamlining a workflow wherein the inspection apparatus is introduced into the conduit and navigates with the fluid motion to aggregate data. The implementation of an attitude determination algorithm rooted in the extended Kalman filter underpins the processing of sensor-acquired data, yielding precise tridimensional attitude measures. Additionally, a refined peak-to-peak anomaly detection technique, based on an adaptive peak algorithm, analyzes the attitude measures to pinpoint deviations in the device's orientation. Empirical evaluations corroborate that the second-generation pipeline inspection device conceived in this study boasts augmented stability and transit efficacy. The integrated approach for attitude calculation and anomaly discernment coalesces data from gyroscopes and accelerometers, guaranteeing meticulous orientation angle computation and enhanced precision in anomaly detection. This accuracy is vital for the accurate replication of the detector's positioning within the pipeline infrastructure and for a comprehensive understanding of the operational state of drainage conduits.