Evidence map›Paper›PMID 40951521›Full record

ArticleThe archives of bone and joint surgery2025

Effects of Prosthesis Shape and Material on the Contact Mechanics of Elbow Joints Following Radial Head Arthroplasty: An In-Silico Investigation.

Faezeh Naghdbishi, Azadeh Ghouchani, Farzaneh Safshekan, Kassem Ghayyad, Amir R Kachooei

Abstract read
In one paragraph

Article in The archives of bone and joint surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Faezeh Naghdbishi
Azadeh Ghouchani
Farzaneh Safshekan
Kassem Ghayyad
Amir R Kachooei

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objectives: Radial head fractures often require prosthetic replacement, but post-surgical complications like radial neck osteolysis, capitellum osteopenia, and ulnohumeral osteoarthritis can arise due to altered elbow biomechanics. This study used the finite element method to evaluate how radial head prostheses (RHPs) shape and material affect elbow joint biomechanics. Methods: A 3D elbow model was developed, including bones, ligaments, and cartilage. Implants featuring two geometries (anatomical vs. axisymmetric) and three materials (polymethylmethacrylate [PMMA], polyether ether ketone [PEEK], and Cobalt) were tested. Bones were considered isotropic and heterogeneous, ligaments and implants linear elastic, and cartilages were considered hyperplastic materials. Stress distributions, contact stresses, and contact areas were assessed during elbow flexion and forearm rotation. Results: During forearm rotation, Cobalt RHPs exhibited lower stresses in the radial neck, indicating higher stress shielding, and all axisymmetric implants showed increased edge loadings. In rotation, only the PMMA anatomic RHP showed close contact stresses to the intact model, while all other models resulted in lower stress levels. In flexion, anatomical designs produced more uniform stress distributions in the radial neck that resembled intact conditions and matched intact capitellum contact stresses, in contrast to axisymmetric designs. The reduction in the contact area in the ulnohumeral cartilage was most noticeable with all axisymmetric RHPs in flexion. Conclusion: The lower contact areas, higher contact stresses, and lower stresses at the radial neck observed in the presence of most axisymmetric RHPs and anatomic Cobalt RHP can be correlated to postoperative complications. The findings suggest that polymeric anatomical RHPs may be superior to conventional metallic axisymmetric options in preserving elbow biomechanics and reducing postoperative complications. However, their long-term effects need to be further explored.

Indexed as

CobaltContact mechanicsFinite element methodPEEKPMMARadial head prosthesis

Identifiers

PMID40951521
PMCPMC12432824

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.