ArticleCureus2025
Conversion to Hip Arthroplasty After Internal Fixation Failure in an Intertrochanteric Femoral Fracture: A Case Report.
Article in Cureus, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Intertrochanteric femoral fractures are mainly managed by internal fixation. However, failures such as over-telescoping, cut-out, nonunion, or implant failure can occur, especially in osteoporotic elderly patients. We report the case of a patient in whom we performed artificial hip replacement surgery after fixation failure following internal fixation of an intertrochanteric femoral fracture. We report the case of an 85-year-old woman who sustained a left intertrochanteric femoral fracture treated with a dynamic hip screw (DHS). One week postoperatively, radiographs revealed over-telescoping of the lag screw. The patient did not complain of pain, but she underwent conversion to cemented bipolar hemiarthroplasty under general anesthesia. One possible cause of over-telescoping of the lag screw after surgery was that the longitudinal fracture line in the calcar of the proximal bone fragment, as seen in the initial CT image, may have extended horizontally at the neck level. During surgery, a fracture at the same site caused the anterior medial fragment to fail, resulting in a coronal shear fracture and fixation failure. When a longitudinal fracture line is observed in the calcar of the proximal fragment, it is necessary to keep in mind that it may extend horizontally at the neck level.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.