Muscle Ultrasound Image Analysis with a Semi-Automated Software (MuscleExpert) Yields Results Comparable to ImageJ: Muscle Thickness, Muscle Area, and Muscle Quality.
Article in medRxiv : the preprint server for health sciences, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
- Updated by
Authors and funding
1 author.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Purpose: The aim of this study is to present and validate the semi-automated MuscleExpert software against the widely used ImageJ by comparing muscle thickness (MT), muscle area (MA), and muscle quality (MQ- measured as grayscale). Methods: Ten volunteers participated in this study. Ultrasound images of the tibialis anterior and medial gastrocnemius muscles were acquired using 2D B-mode ultrasonography and analyzed on both software. Equivalence of means was evaluated via the two-one-sided tests (TOST) procedure, the reliability between means was quantified by an intraclass correlation coefficient (ICC), the precision was expressed as the coefficient of variation as well as standard error of measurement (SEM), and the agreement across the measurement was assessed using Bland-Altman plots. Results: The TOST for MT, MA, and MQ was within their respective equivalence margins. The ICC was excellent for all measures (MT: ICC=0.999; MA: ICC=0.999; MQ: ICC=1.000). Precision was similarly high, with CVs of 0.49% for MT, 0.54% for MA, and 0.33% for MQ, demonstrating minimal variability between the two methods. SEM values were low across all outcomes, corresponding to 0.49 % for MT, 0.53% for MA, and 0.23% for MQ. Finally, the Bland-Altman analysis demonstrated minimal systematic differences and no proportional bias between ImageJ and MuscleExpert for all three metrics. Conclusion: The present findings indicate that MuscleExpert and ImageJ produce nearly identical results for MT, MA, and MQ. These findings support the integration of MuscleExpert into clinical and research workflows, offering a more efficient solution for muscle assessment without compromising measurement integrity.